TP-6100A Automatic-Cleaning Dielectric Loss And Resistivity analyzer For Insulating Oil
TP-6100A Automatic-Cleaning Dielectric Loss And Resistivity analyzer For Insulating Oil
TP-6100A Automatic-Cleaning Dielectric Loss And Resistivity analyzer For Insulating Oil
TP-6100A Automatic-Cleaning Dielectric Loss And Resistivity analyzer For Insulating Oil

TP-6100A Automatic-Cleaning Dielectric Loss And Resistivity analyzer For Insulating Oil

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Chongqing Top Oil Purifier Co., Ltd

Business Type: Association
Main Products: , , ,

Product Details

TP-6100A Automatic-Cleaning Dielectric Loss And Resistivity analyzer For Insulating Oil

TP-6100A Insulating oil dielectric loss and resistivity tester complies to ASTM D924, IEC and GB/T5654-2007 Liquid Insulating Material Relative Permittivity, Dielectric Loss Factor And DC Resistivity Measurements. Used for measuring the dielectric loss factor and DC resistivity of insulation oil and other liquid insulating medium. It is characterized by integrated structure, and integrates the dielectric loss of grease cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. The instrument adopts intelligent automatic measurement, equipped with large screen (240*128) LCD display. Test results can be automatically stored and printed out so that the operator without professional training can use it easily.
> Oil cup uses a three-electrode structure in line with GB / T5654-2007, the inter-electrode spacing of 2mm, can eliminate the impacts of stray capacitance and leakage impact on the dielectric loss test results. It has a drain solenoid switch, you can drain all the sample oil in the oil cup without removing the oil cup and rinse the oil cup with sample oil.
> The instrument uses mid-frequency induction heating, PID temperature control algorithm. This heating method has some advantages, eg, oil cup and heating body non-contact, heating evenly and quickly, also easy to control, thus the temperature strictly controlled within the preset temperature range of error.
> Internal standard capacitors for SF6 inflatable three-pole impact of capacitors, the capacitor dielectric loss and electrical
capacity are not affected by ambient temperature, humidity etc to ensure that the instrument is still consistent accuracy after prolonged use.
> AC Test Power Supply with AC-DC-AC conversion, effectively prevent affecting of the dielectric loss test accuracy for the mains voltage and frequency fluctuations, even the generator generate electricity, the instrument can also run properly.
> Complete protection. When there is over-voltage, over-current, short-circuit for high-voltage, the instrument can be quickly cut off the voltage and warning. When the temperature sensor fails or is not connected, the instrument will give a warning message. there is a limiting temperature relay amounted in the mid-frequency induction heating furnace, when the temperature exceeds 120 degrees, the relay release, then the heating stop.
> easy to set the parameters. Temperature setting range 0 ~ 125 ℃, the AC voltage setting range 500 ~ 2200V, the DC voltage setting range 0 ~ 500V.
> Large-screen LCD display with backlight, clear display. Friendly interface, simply follow the English menu prompt, enter the command, the instrument can be automatically tested. And automatically store and print test results.
> With real-time clock, test date and time can be saved with the test results, display and print.
> Empty electrode cup calibration. measuring capacitance and dielectric loss factor of empty electrode cup to determine the status of empty electrode cleaning and assembly of the cup. Calibration data is automatically saved, conducive to calculate the relative permittivity and DC resistivity precisely.
> Power supply: AC 220V ± 10%, 50Hz / 60Hz ± 1%
> Measuring range: capacity: 5pF ~ 200pF
Relative permittivity: 1.000 to 30.000
Dielectric loss factor: 0.00001 to 100
> DC Resistivity: 2.5 MΩm ~ 20 TΩm
> measurement Accuracy: Capacitance: ± (1% of reading + 0.5pF)
Relative permittivity: ± 1% of reading
Dielectric loss factor: ± (1% reading +0.0001)
DC resistivity: ± 10% of reading
> Resolution: capacity: 0.01pF
Relative permittivity: 0.001
Dielectric loss factor: 0.00001
> Temperature range: 0 ~ 125 ℃
> Temperature measurement error: ± 0.5 ℃
> AC test voltage: 500 ~ 2200V continuously adjustable frequency 50Hz
> DC test voltage: 0 ~ 500V continuously adjustable
> Applicable Temperature: 0 ℃ ~ 40 ℃
> Applicable Humidity: <75% RH
> Power: 100W
> Size: 500×360×420 mm
> Weight: 22Kg

1.1.Fully Automatic Karl Fischer Water Content Tester TP-2100
2.Digital Karl Fischer Water Content Tester TP-6A
3.Kinematic Viscosity Tester VST-2000
4.Kinematic Viscosity Tester TPV-8
5.Kinematic Viscosity Tester VST-3000
6.Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
7.Fully Automatic Surface/Interface Tension Tester IT-800

8.Automatic Surface/Interface Tension Tester (Platinum Plate Method) IT-800P
9.Fully Automatic Open Cup Flash Point Tester TPO-3000
10.Fully Automatic Closed Cup Flash Point Tester TPC-3000
11.Digital Open Cup Flash Point Tester TPO-100
12.Digital Closed Cup Flash Point Tester TPC-100
13.Cloud Point & Pour Point Tester PT-2000

MOQ
1 Set
Trade Terms
EXW, FOB, CIF, CFR
Payment Terms
T/T, L/C
Port of Loading
Any Port of China
Packing Method
Internaional Standard Wooden Case
Transportation Method
By Sea, By Land, By Air, By Express
Supply Capability
100 Sets/Month

* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.

Chongqing TOP Oil Purifier Co., Ltd

Located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality, Chongqing TOP is a professional leading manufacturer and supplier of oil purifiers and various related testers. Our company consists of departments respectively for technological development, machinery manufacture, instrument manufacture and quality control etc.

Welcome to visit our website, welcome your inquiry.

Mia (Miss) | Sales Manager
CHONGQING TOP OIL PURIFIER CO.,LTD
Manufacture oil purifiers and supply test equipment.
Add: No. 1, Jianlong N. Rd., Jiulongpo District, Chongqing, China
E: sales10@topoilpurifier.com
Cell: 0086-13983286435 (Whatsapp/Wechat) | Skype: topoilpurifier
Tel: 0086-23-88901306 | Fax: 0086-23-88901306
;

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~