AG-BZ014 Medical Multi-Parameter Patient Monitor

AG-BZ014 Medical Multi-Parameter Patient Monitor

USD $500 - $1000 /Piece

Min.Order:1 Piece

Supply Ability:
500 Piece / Pieces per Month
Port:
Shnaghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
30 days

Quick Details View All >

Brand Name:
Medwish
Place of Origin:
China
Model Number:
AG-BZ014 Medical Multi-Parameter Patient Monitor
Type:
Other, AG-BZ014 Medical Multi-Parameter Patient Monitor

Jiangsu Medwish Network Technology Co., Ltd.

Business license
Business Type: Trading Company
Suzhou Jiangsu China
Main Products: Hospital Bed ,Hospital Bed Mattress ,Operating Table ,Hospital Trolley ,Gynecological Exam Table ,Surgical Lamp ,Examination Couch

Product Details

AG-BZ014 Medical Multi-Parameter Patient Monitor
Patient Monitor
Introduction
This patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
Optional
-Built-in recorder and battery and printer -Central Station Software -Switch
-An optional USB Mouse/Keyboard control eases navigation and data entry.
-An optional HDMI output eases observation from a long distance.
Features
-12.1" color TFT display, up to 12 waveforms -One level menu, easy to use
-Parameters includingECG/SpO2/PR/TEMP/ NIBP/HR
-Maximum 720 hour graphic and tabular trends of all parameters
-Built-in recorder and battery and printer
 Suitable for adult, pediatric and neonatal patient Arrhythmia analysis,ST calculation, Pace analysis -Anti-ESU,anti- defibrillator
-Standard network interface, can connect to Central monitor system
Core
• Newly advanced A8 main board with Linux OS, calculating speed is 4 times faster than traditional products
• Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events reviewBody
• 12.1 inch high-brightness TFT LED
• Support display 9~13 waveforms
• Support 7 channel ECG waveform display simultaneously  
• Optional touch screen
• Optional HDMI output
Printer
• Built-in high-speed 50mm thermal printer
• Central System
• Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
• Optional Support HL7 (Health Level Seven)
• Drug calculation and titration table 
• Support multi-language display
Alarm
• Three-level acousto-optic alarm
• Sensor-off alarm
• Paper out alarm
• Support alarm review 
• Support alarm pause
Linux OS
• Support operation with mouse and computer keyboard (option)
• Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
• NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
• Generate ID automatically when register a new patient
• Support medical history search by patient ID, name and mobile number
• 18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
• Support online software upgrading by net/USB
Performance Specifications 
Dimension and Weight
• Dimension: 310mm*290mm*150mm
• Weight: 3.4kg(excluding accessories)
System Output & Extensible Interface
• Ethernet Network: 1 standard RJ45 socket
• USB Port: 1
• Video Output: 1 HDMI port (option)
ST Measurement
• Range: -2.0 ~ +2.0 mV/Resolution: 0.01mV
• Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, 
whichever is greater
• Other range:unspecified


Respiration
• Method: Impedance between RA-LL, RA-LA
• Gain: ×0.25, ×0.50, ×1, ×2, ×4
• Respiration Rate: 0bpm, 6 ~ 150 BrPM
• Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
• Resolution: 1 BrPM
• Accuracy: ±2 bpm or ±2%, whichever is greater
• Apnea Alarm: 10 ~ 60 s


NIBP
• Method: Oscillometric
• Measure mode: Manual, Auto, STAT
• Measure Interval in AUTO Mode 1~480 min
• STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
• Measure and Alarm Range: 
 Adult: SYS:  30 ~ 270 mmHg
           DIA:  10 ~ 220 mmHg     
           MEAN:  20 ~ 235 mmHg
Pediatric: SYS:  40 ~ 235 mmHg
              DIA:  10 ~ 220 mmHg     
             MEAN:  20 ~ 225 mmHg
Neonate: SYS:  30 ~ 135 mmHg
               DIA:  10 ~ 110 mmHg     
             MEAN:  20 ~ 125 mmHg
• Static pressure accuracy: ±3mmHg
• Resolution: 1mmHg
• Accuracy: Maximum Mean error ±5mmHg
                 Maximum Standard deviation ≤8mmHg
• Over pressure Protection:
Dual protection via software & hardware

Temperature
• Technique: Thermistor probe (2.25K)

• Channel:  Dual-channel, provide T1; T2; ΔT
• Measuring and Alarm Range:
   0.0 ℃~ 50 ℃ (32℉~ 122℉)
• Unit: Celsius (℃), Fahrenheit ( ℉)

• Resolution: 0.1℃or 1℉
• Accuracy: ±0.1℃(exclusive probe)
Power Supply
• Voltage: AC100~240V, 50/60HZ, Power≤60W
Display
• 12.1" color TFT LED  
• Resolution: 800*600 pixels
Battery (Pluggable)
• Type: Rechargeable lithium battery 14.8V/2200mAh
• Charge Cycle: ≥500 times
• Working time: 2 hours (optional larger battery for 4-5 hours)
Operating Environment
• Temperature:  5 ~ 40 ℃
• Humidity:  15% ~ 80% (non-condensing)
• Atmosphere pressure:  86 KPa ~ 110 KPa
Transportation and Storage Environment
• Temperature:  -20~50 ℃
• Humidity:  10%~90%  (non-condensing)
• Atmosphere pressure:  86 KPa ~ 110 KPa



 
Recorder (Option)
• Method: Thermal printer
• Paper width: 50 mm (1.97 in)
• Printing speed: 12.5/ 25/ 50 mm/s
• Trace: Max. 3 tracks
• Recording way:
Real-time Recording, Review Printing,      
Periodic Recording, Alarm Recording
Safety
• IEC60601-1 Approved, CE marking according to MDD93/42/EEC
• With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
• Trend: 2160 hours
• ARR events: 128 groups of ARR events and associated waveform
• NIBP measurement reviewing: 2000 groups
• Waveform review: 2 hours
• Alarm event:2000 groups of parameter alarms events and associated parameter
Alarm
• Level: Low, medium and high
• Indication: Auditory and visual
• Alarm volume adjustable
• Alarm pause time: 1min, 2min
• Parameter alarm type: Latch/ Unlatch

Input Device
• Touch screen (option)
• Knob (Standard)
• Keypad input (Standard)
• Mouse/ Keyboard input (option)

Heart Rate
• Measure range: Adult: 0bpm; 10 ~ 300 bpm
• Neo/Ped: 0bpm; 10 ~ 350 bpm
• Resolution: 1 bpm
• Accuracy: ± 1% or ± 1bpm, whichever is greater
ECG
• Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
• Protection: Breakdown Voltage 4000VAC 50/60Hz;
Defibrillator proof
• Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5),
10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
• Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
• ECG signal range:  ±12 mV (Gain × 0.25)
• Accuracy: ±1bpm/ ±1%, whichever is greater
• Resolution: 1 bpm
• Leakage Current<10 μA
• Baseline Recovery:
                            ≤ 3s after defibrillation (Monitor mode)
                            ≤ 1s after defibrillation (Surgery mode)
• Bandwidth: Surgery 1 ~ 25 Hz
                     Monitor 0.5 ~ 40 Hz
                     Diagnostic 0.05 ~ 120 Hz
• Indication of Electrode Separation:
  Every electrode (exclusive of RL)

 
Model Configuration
Standard Config.12.1 inch LED, 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration
Optional Config.1/2 IBP, 2-Temperature, Nellcor SpO2, Masimo SpO2,
EtCO2 (Mainstream/Sidestream/Microstream),
Anesthesia Depth Monitoring (CSM module),
Multi-gas (AG) Monitoring
Optional Accessories:Touch Screen, Printer, USB Mouse/Computer Keyboard Input Function,
Central Monitoring Station,
Neo/Ped Accessories,
HDMI Output, Wall-mounting, Trolley,
Remark:The touch screen and USB mouse/ computer keyboard is not compatible by now.


Contact Supplier

Ms. Wu Chat Now
Telephone
86-0512-1996521
Mobile
86-15250424276
Address
zhangjiagang Suzhou,Jiangsu

You May Like