Low voltage super reactive power compensation module smart capacitor bank
Negotiable
Min.Order:1
Jiangsu Sfere Electric Co., Ltd.
200kvar reactive compensation power factor correction super capacitor bank
300kvar quick response PFC power factor correction cabinet capacitor
100 kvar 3 phase reactive power compensation capacitor bank low price
Elecnova-BCM101 multi channel data logger data center monitoring
Elecnova cloudview software data real time measuring analysis energy monitor system
*Improve efficiencies on power system
*power factor correction
*harmonic voltage
*system capacity release and reduced system losses
Dimension: 392mm*110mm*363mm (SFR-LXD-4020/450)
Compensation mode:
G indicateds three-phase total compensation
F indicates combined compensation
Function | Specification | |
Measurement accuracy | Current | ≤1.0%(5%~120%In) |
Voltage | ≤0.5%(80%~120%Un) | |
Power | ≤2% | |
Power factor | ≤0.01 | |
Switching mode | Zero cross switching | |
Compensation operation | Working voltage | AC380V±20%, distortion rate ≤5% |
Comsumption | ≤5VA | |
Max working current | 1.35 X In | |
Switching inrush current | ≤3 X In | |
Host protection | Over voltage | 430V(can be set) |
Under voltage | 300V(can be set) | |
Harmonic exceeding | 0%~100% | |
Local protection | Over current | 0A~100A |
Over temperature | 55 ℃ | |
Unbalance | 50% | |
Control setting | Control parameter | Target power factor, switching threshold, delay time etc. |
Peripheral unit parameters | Current transformer ratio | |
Network interface | Pluggable data line, internal network protocol | |
Mechanical installation | Outline dimension | W-71.5mm L-370mm, height is a according to different capacity |
Installation dimension | Distance of installation fixing holes:W-85mm*L-315MM | |
Weight | ≤6.5kg | |
Environment temperature | Working temperature | -15℃~45℃ |
Storage temperature | -25℃~55℃ | |
Altitude | ≤2000m | |
Standard | GB/T15575-2008 |
Compensation mode | Capacity(kvar) | Model | Application field |
40+40 | SFR-LXD-4040/450 | It is used in the fields where the power quality meets the national standard, the requirement for power quality is not very high and no harmonic sensitive equipment. Phase separation compensation is used in the occation that three phase load imbalance greater than 30%. | |
40+20 | SFR-LXD-4020/450 | ||
30+30 | SFR-LXD-3030/450 | ||
20+20 | SFR-LXD-2020/450 | ||
20+10 | SFR-LXD-2010/450 | ||
10+10 | SFR-LXD-1010/450 | ||
10+5 | SFR-LXD-1005/450 | ||
30 | SFR-LXD-30/250 | ||
20 | SFR-LXD-20/250 | ||
10 | SFR-LXD-10/250 | ||
5 | SFR-LXD-05/250 | ||
40+20 | SFR-LXD-40G20F | ||
40+15 | SFR-LXD-40G15F | ||
40+10 | SFR-LXD-40G10F | ||
30+20 | SFR-LXD-30G20F | ||
30+10 | SFR-LXD-30G10F | ||
20+20 | SFR-LXD-20G20F |
Q: Does your company provide customized manufacturing?
A: We provide OEM/ODM service to our customers. Our experienced R&D team will give our customer solution in a high efficiency way.