KEC990 Portable Air negative oxygen ion detector
Negotiable
Min.Order:1
Dongguan NAPUI Electronic Technology Co., Ltd.
1.1measurement of health products, textile, dynamic friction measurement (proposed matching EST-101CH anion collector)
1.2University, Department of landscape and forestry investigation, scenic, ecological and meteorological measurements and evaluation
1.3testing center assessment and programme implementation
1.4Air Purifier negative ion generator, nebulizer product effectiveness assessment testing
1.5indoor and outdoor air quality assessment test
1.6technical seminars, and publish
1.7measurement of health products, and textiles.
1.8anions, such as nano-materials testing.
2.Technical specifications
2.1the sensor principle: gold-plated polarized parallel electrodes
2.2test object: the air of positive and negative ions
2.3air velocity: design to 600 cm3/sec, 75% design can be gleaned from the ions in the air. Note When the battery is low, fan speed will be reduced, actual measurements, when you faster than the default 80cm/sec, collected ions will be higher than 75% and vice versa when the speed is lower than 60cm/sec, and collected ions can 75%. Recommended for everyday use AC power supply, to provide more stable power supply.
2.4measuring range:
Range Model | KEC900+
| KEC990+
| KEC990M |
H(ions/cm3) | 10-19,990 | 100~199,900 | 1,000~1,999,000 |
L(ions/cm3) | 1,000-1,999,000 | 10,000~19,990,000 | |
M(ions/cm3) | 100-199,900 | 1,000~1,999,000 | 10,000~19,990,000 |
Output | DC-1.999~1.999V | DC-1.999~1.999V | DC-1.999~1.999V |
2.5accuracy: better than ± 20%
2.6resolution: 10ions/cm3
2.7power supply: rechargeable lithium-ion battery and DC12V power adapter
2.8environment: 5~45℃, 75%, R.H. (no condensation)
2.9size: (l) 105mmx (w) 70mmx (h) 165mm
2.10weight: about 760g
2.11the standard configuration: manual, AC100-240V adapter, grounding cable, electrostatic shielding panels, analog signal output port using the device line.
3.Measurement accuracy
3.1High sensitivity gold plated sensor 1, leading, greatly improving the measurement accuracy and stability
3.2 in line with the "standard method of measurement of gas density" measurement requirements
3.3switch gears to ensure measurement accuracy
3.4switching, positive and negative ions
3.5Intelligent optimization circuit inside the 5, and ensure the smooth flow of
3.6equipped with shielding plate to effectively prevent interference of electrostatic and atmospheric flow, provide a measure of stability
4.Extensibility
4.1Integrated analog signal output port 1, the fuselage and external large screen display device or connect recording equipment
4.2bottom, a tripod-mounted, fixed triangle feet for prolonged inspections
4.3built-in high capacity rechargeable lithium battery and interface DC12V power supply for easy carrying.
4.4integrates the fuselage external power connectors, external AC power line long continuous monitoring.