SFR-SVG kvar wall mounted static var generator power factor correction equipment
Negotiable
Min.Order:1
Jiangsu Sfere Electric Co., Ltd.
Power distribution wall mounted 30-150 A power quality active harmonic filter
Energy saving equipment wall type AHF Power Distribution Equipment
Elecnova SFR-SVG anti-harmonic reactive compensation static var generator
Elecnova wall-mounting type low voltage anti-harmonic reactive compensation static var generator SVG
Elecnova heavy industry dynamic smooth reactive compensation static var generator
Active Harmonic Filter (AHF), Active Power Filter (APF), Automatic Power Factor Correction
Function | Technical parameters | Wall mounted SFR-SVG-(30~50)/B | Rack mounted SFR-SVG-(30~200)/M | Cabinet type SFR-SVG-(100~500)/G | |||
Electrical characteristics | Rated voltage(V) | AC380V±15%, AC690V±15% | |||||
Working frequency(Hz) | 50Hz±5% | ||||||
Rated compensation capacity(KVA) | 30 50 | 30 50 75 100 150 200 | 100~500 | ||||
Scope of reactive adjustment | Continuously adjustable from rated induced to rated capacitive | ||||||
Response time | 5ms | ||||||
Loss of active power | <3% rated module power | ||||||
Over-load capability | 120% | ||||||
Multi-set running mode | Parallel running | ||||||
Mean time between failures | ≥100,000hours | ||||||
Local protection | Switching frequency | Average 10kHz | |||||
Control algorithm | compensation algorithm of screening vector of frequency domain possessing self-adaptation capability | ||||||
Controller | Digital signal processor(DSP) | ||||||
Communicationcapability | Adopting Modbus remote communication protocol,communication interface RS485/232 and CAN bus | ||||||
Control connection | Optical fiber or electrical connection | ||||||
Structural characteristics | W x H x D(mm) | 510 x 218 x 694 | 340 x 629 x 709 | Refer to capacity of cabinet | |||
Protection grade | IP21 orcustomized according to the user' s demand | ||||||
Color | RAL7035(light gray), | ||||||
Cooling mode | Forced air cooling | ||||||
Overall structure | Floor type | ||||||
Installation mode | Indoor installation; optional fixing modes and optional cable incoming modes | ||||||
Environmental conditions | Environmental temperature | -10~40℃ | |||||
Storage temperature | -40~65℃ | ||||||
Relative humidity | 5%-95%, no condensation | ||||||
Altitude | ≤1000m,1000-4000;according to national standard GB/T3859.2, for every increased 100m, the power is reduced by 1% | ||||||
Electromagnetic compatibility | Conforming to GB/T7250-2005 |
Transformer Capacity(kVA) | Three-phase Four-wire | Three-phase Three-wire |
200 | SFR-SVG4-100/0.4 X 1 | SFR-SVG3-100/0.4 X 1 |
250/315 | SFR-SVG4-100/0.4 X 1 | SFR-SVG3-100/0.4 X 1 |
400 | SFR-SVG4-150/0.4 X 1 | SFR-SVG3-200/0.4 X 1 |
500/630 | SFR-SVG4-200/0.4 X 1 | SFR-SVG3-300/0.4 X 1 |
800 | SFR-SVG4-250/0.4 X 1 | SFR-SVG3-400/0.4 X 1 |
1000 | SFR-SVG4-300/0.4 X 1 | SFR-SVG3-500/0.4 X 1 |
1250 | SFR-SVG4-400/0.4 X 1 | SFR-SVG3-300/0.4 X 2 |
1600 | SFR-SVG4-250/0.4 X 2 | SFR-SVG3-400/0.4 X 2 |
2000 | SFR-SVG4-300/0.4 X 2 | SFR-SVG3-500/0.4 X 2 |
2500 | SFR-SVG4-400/0.4 | SFR-SVG3-400/0.4 X 3 |