Fire Fighting Pipe
USD $10 - $300 /Bag
Min.Order:100 Bags
Hebei Tianchuang Pipe Co., Ltd. was invested and founded by Xinfangsheng Holding Group, and is one of the key projects in Hebei Province. It is located in Handan, a city seated at the junction of Shanxi, Hebei, Shandong and Henan and known for its prolonged history and profound culture and for its surprising china steel pipe production.
Fire hydrant pipe is a kind of normal carbon steel pipe for conveying water, gas and other fire pipe supply agents. It's usually in red. But the exterior of the light-wall pipes is galvanized silvery. The installation of a red steel pipe is only to be used as a wet sprinkler system. Dry and wet pipe sprinkler systems (including pre-action pipe sprinkler systems) are allowed to install galvanized pipes.
Since the installation of the first fire protection pipe system, black steel has been the traditional leader of the fire sprinkler pipe market because of its strength, durability, and extreme resistance to heat exhibited. With a melting point between a whopping 2,600°F and 2,800°F (1,427°C and 1,538°C), steel pipe can withstand the heat of burning buildings, it even can keep water flowing over a fire.
Steel Pipe for Fire Protection Pipe Systems
Fire suppression pipe is easy to form, bend, and fabricate, which can be manufactured in various sizes, shapes and configurations. Steel pipe has been the main material of sprinkler piping systems for a long time. Steel is considered strong, durable and resistant to fire. With a melting point of about 2,700°F, the fire service pipe can withstand the heat of a burning building.
Steel fire sprinkler pipe can be connected by screw thread, welded connection, rolling connection and groove cutting connection. Threading is only allowed for Schedule 40 or heavier pipe. However, if a lighter wall pipe is listed by a specialized thread testing laboratory, NFPA 13 (National Fire Protection Association) will allow the lighter wall pipe threads.
Fire Fighting Pipe's National Standard
GB/T5135.20-2010 standard
GB/T17219-1998 standardCJ/T120-2008 standard
GB50261-2010 national standard automatic sprinkler system Part 20: Coated steel pipes
Fire Fighting Pipe's Technical Parameter
Coating material: modified heavy anti-corrosion epoxy resin
Universal color: red
Coating thickness: 250um-550 um Coating method: Fluidized bed impregnation process, one-time film formation.
Fire protection piping specifications: DN15-DN1200
Ambient temperature: -30 ° C to 80 ° C (peak 760 ° C)
Regular pressure: 0.1Mpa-2.5Mpa
Connection method: thread, groove, flange connection, etc.
Application areas: fire water supply, gas supply, foam medium conveying pipeline system