Acrel ADL200 Din rail energy meter/single phase electric meter/1 phase energy meter CE-MID
Acrel ADL200 Din rail energy meter/single phase electric meter/1 phase energy meter CE-MID
Acrel ADL200 Din rail energy meter/single phase electric meter/1 phase energy meter CE-MID
Acrel ADL200 Din rail energy meter/single phase electric meter/1 phase energy meter CE-MID
Acrel ADL200 Din rail energy meter/single phase electric meter/1 phase energy meter CE-MID

Acrel ADL200 Din rail energy meter/single phase electric meter/1 phase energy meter CE-MID

USD $35 - $35.1 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
ADL200
Phase:
Single Phase
Output Voltage:
220V
Operating Temperature:
-25℃~55℃

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

General
ADL200 din rail energy meter adopts DIN35mm din rail installation with LCD display,it can measure electric parameters and has energy pulse output, RS485 communication,which has the advantages of small size, high precision, good reliability and convenient installation.


Parameters

Voltage
Rated voltage
AC 220V
Rated frequency
50Hz
Consumption
<10VA
Current
Maximum current
80A
Starting current
0.01A
Consumption
<1VA
Measurement performance
Accurary
kWh Class 0.5
Range
0-99999999kwh
Clock
Accurary
Error≤0.5s/d
Active pulse
Width
80±20ms
Constant
1000imp/kWh,10000imp/kWh
Communication
Interface
RS485
Protocol
Modbus-RTU
Temperature range
Work
-25℃-55℃
Storage
-40℃-70℃
Humidity
≤95%(No condensation)
Altitude
<2000m

FAQ








Q:The display power or energy count is inaccurate after the meter powered on.

A:Switch the meter display interface to the power (active power P, power factor λ) interface, and check whether the power display is negative or not.And whether the power factor is between 0.9-0.95, and then check whether the incoming and outgoing wires of the current signal wire are connected reversely (that is, the current The incoming wire must be the same as the incoming wire end of the meter), and consistent with the wiring diagram on the meter.

Q:It cannot communicate with the host computer normally after the instrument powered on.

A:1. The voltage value between the communication output A and B of the measuring instrument should be between +(4.4-4.5)V .

   2. Check whether the communication wiring method is correctly wired according to the wiring diagram (that is, the communication terminal A/B of the instrument must be connected with Corresponding to communication serial port A/B);


Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~