Max Gas Separator Membrane Permeability Test With Gas Chromatograph
Negotiable /Unit
Min.Order:1 Unit
Systester Instruments Co., Ltd
Oxygen Transmission Rate Test Gas Adjustment Packing (MAP) Oxygen Permeability Testing Machine
Flexibla Packaging Hot Tack Tester Thermal Viscosity Test Of Heat Sealing
Lithium Battery Performance Test Air Permeability Tester Different Pressure Method
Electrical Aluminum Peeling Test High Temperature Peel Testing Machine
Nonwoven Fabric Material Transmittance Test Water Vapor Permeability Tester
Gas Permeability Tester Composite Polymer Membrane Transmission Test GTR/ OTR
Max Gas Separator Membrane Permeability Test With Gas Chromatograph
Catalogs
What we can provide
Packages & Logistics
About Quality
Peoduct
Application
Based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Max Gas Separator Membrane Permeability Test With Gas Chromatograph
Features
Vacuum differential pressure method
Own technology
3 specimens test simultaneously and independently
Computer control
One-button test, test automatically through whole process
High accuracy vacuum sensors embedded in
3 Chambers with independent temperature sensor
Test under various RH conditions with Humidity generator (optional)
Environment temperature and humidity sensor inside
Permeability coefficient ,solubility coefficient and diffusion coefficient test Chambers with water bath temperature control technology
Unit based on embedded system,24bit Δ-Σ AD
Multiple test modes optional
Data curves display
Traceable reference film calibration
Supports DSM system (DSM, lab data management system)
Max Gas Separator Membrane Permeability Test With Gas Chromatograph
Technical Indexes
Test range: 0.01 - 190,000 cm3/m2 ·24h·0.1MPa (Standard)
Resolution: 0.001cm3/m2 ·24h·0.1MPa
Samples: 3, independent
Vacuum accuracy: 0.1Pa
Temperature range: 5C - 95C
Temperature accuracy: ±0.1C
Humidity range: 0%RH,35%RH-90%RH,100%RH (optional)
Humidity accuracy: ±1%RH (optional)
Sample thickness: less 5mm
Sample size: >= 150mm * 94mm
Test area: 48cm2 Test gas: O2, N2, CO2, He, etc(Flammable or toxic gases test available: H2, CH4, H2S, C2H2,C2H4 etc, must be announced in advance)
Differential pressure: -0.1MPa-0.1MPa(Standard)
1.0MPa, 4.0MPa(optional)
Gas interface: Ф8mm
Contact