We usually use nozzle on machines,always face problems,so what can we do and in case them don't happen again?
Here Let's see NPM CM panasonic machine nozzle,Top 6 Daily Maintenance Manuals
1, surface of the SMT nozzle is cleaned with a dust-free cloth;
2, Separate and soak the nozzle and holder,Small aperture nozzle can be opened with a thin steel wire, blowing it to pass;
3, the surface of the nozzle can not be soaked with corrosive solution such as alcohol, otherwise the surface will fall off;
4, HOLDER wipe the cavity with a cotton swab, do not smash the filter;
5, HOLDER minions regularly add special grease;
6, according to the production * good regular maintenance, usually do other maintenance
Below we will give an example to explain the nozzle of the following machine,
Model: Panasonic CM602/CM212 nozzle NOZZLE is maintained in series order:
1, the needle cleans the nozzle rod;
2, wipe the reflector;
3, check the nozzle rod for deformation
4. Blow the nozzle rod.
5, load the machine to check the vacuum value is CM602 less than -85 is OK. CM212 is less than -65 is OK.
The MSH3 nozzle operates as follows:
1. Soak the nozzle into the alcohol box for about 10 minutes.
2, clean the nozzle rod with a needle
3, blowing the nozzle rod
4. Visually check that there is no blockage in the nozzle rod.