Din Rail Digital DC Energy Power Meter  for charging stations
Din Rail Digital DC Energy Power Meter  for charging stations
Din Rail Digital DC Energy Power Meter  for charging stations
Din Rail Digital DC Energy Power Meter  for charging stations
Din Rail Digital DC Energy Power Meter  for charging stations

Din Rail Digital DC Energy Power Meter for charging stations

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

DJSF1352-RN rail-mounted DC power meter

Product Description

Characteristic

DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base
stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.
The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input
function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), maximum and minimum value recording function of voltage and current power.
Specification
Technical parameters
Index
Input
Nominal value
Voltage input range
Current input
DC0-1000V 
Shunt:0-75mV
Hall sensor:0-20mA,4-20mA,0-   5V,0-10V and so on.
Overload
1.2 times rated(continuous);2 times rated/1 second;
Power consumption
Voltage:≤0.2VA, Current:≤0.1VA
Accuracy class
class 1
Function
Display
8-bit segment LCD screen (LCD)
Communication Interface
RS485, infrared
Communication protocol
Modbus-RTU,DL/T 645-2007
Switch
Switch output
2 Relay outputs, 2A/30VDC or 2A/250VAC
Switch input
2 dry contact inputs
Pulse output
A second pulse output, a energy pulse output
See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWH
Power Supply
Voltage range
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
Power consumption
≤ 3W
Power frequency withstand voltage
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output
3kV/1min Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch
input 2kV/1min
Insulation resistance
≥ 40M Ω
Average barrier-free working hours
≥50000h
Environment
Temperature
Normal operating temperature: -25 °C ~ +55 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+70℃
Humidity
≤93%RH, no condensation, no corrosive gas
Altitude
≤2500m
Installation

Product installation

The meter is designed by standard DIN35mm rail mounted.


Terminals and wiring

Note: The second DC input channel and DI and DO functions are optional. When the current input mode is current shunt input:

More Type
Type
Function
FOB Shanghai(USD)


DJSF1352-RN
1. DC voltage, current, power measurement
2. Forward and reverse energy measurement
3. RS485 and infraredCommunication
4. Time sharing and multi rate energy measurement
5. SOE Sequence Of Event record


103.6
DJSF1352-RN/K
On the basis of DJSF1352-RN, add the switch function(2DI/2DO)
124.4
DJSF1352-RN/D
On the basis of DJSF1352-RN, add the second channel of energy measurement
124.4
DJSF1352-RN/KD
On the basis of DJSF1352-RN, add the second channel of energy measurement and switch function(2DI/2DO)
145
Packing & Delivery
Company Profie

Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~