Arm type Centrifugal Constant Acceleration Tester
USD $25000 - $100000 /Set
Min.Order:1 Set
Hyde Science and Technology Limited
Arm type Centrifugal Constant Acceleration Tester
KCT31 series arm rotating constant acceleration test system is used to determine whether the structural adaptability and performance are in good condition or not when the components and parts, devices and other electric and electronic products are subjected to the force (gravity is not included) given by steady-state acceleration (also called constant acceleration) environment, to evaluate the structural integrity of some components, and to check the electrical parameters of test specimen in the constant acceleration environment, and to verify if the product can work normally and the bearing capacity of structure subjected to the constant acceleration stress in the expected environment.
Functions and features:
◆ Advanced control system: full-automatic computer remote real-time control interface, the operator only needs to input a simple value to start the device and accurately complete the acceleration test;
◆ User-friendly display interface: the control interface can display test curve, tolerance and test time in real time;
◆A powerful multi-acceleration continuous test system: multi-stage acceleration continuous test can be realized according to the different requirements of the test sample;
◆ Reliable protection measures: provide open circuit, over limit and over speed protection;
◆ Multiple control methods: The device can still be manually controlled to complete the test without automatic control or automatic control failure;
◆ Provide the most realistic test environment: During the test, the sample can be supplied with liquid, air and power, and the state of the sample under acceleration can be reproduced realistically;
◆ Full-range multi-directional monitoring system: It can perform dynamic and static monitoring on equipment operation and samples test status, that is, it monitors the equipment and samples in real time during the whole test process;
◆ Convenient and quick result output system: After the test is over, the test report is automatically generated and printed out.
Technical parameter:
Model | KCT31-30 | KCT31-50 | KCT31-100 | KCT31-100A |
Max. load (kg)/ position | 30*2 | 50*2 | 100*2 | 100*2 |
Acceleration (m/s2) | 30~1000 | 30~1000 | 30~1000 | 30~1000 |
Max. specimen size (mm) | 300*300* 300 | 400*400* 400 | 500*500* 500 | 500*500* 500 |
Specimen installed radius (mm) | 1000 | 1200 | 1500 | 2250 |
Start time (min) | ≤3 | ≤3 | ≤3 | ≤3 |
Stop time (min) | ≤3 | ≤3 | ≤3 | ≤3 |
Continuous working time (min) | 60 | 60 | 60 | 60 |
Consumption power (kVA) | 40 | 40 | 40 | 55 |
Pit diameter (mm) | Φ3000 | Φ4000 | Φ4500 | Φ6000 |
Power connecting device | 60 conducting ring, 500V 5A | |||
Weight (kg) | 2500 | 2800 | 3000 | 3500 |
Power supply | Three-phase, 380V, 50/60Hz | |||
Measurement and control system | Computer automatic control and manual control | |||
Remark | Power connecting device and control accuracy can be configured according to related standards or customer’s requests. | |||
Environment | Temperature: 0~40℃, humidity: ≤80%, non condense |
Model | KCT31-200 | KCT31-500 | KCT31-1000 | KCT31-1500 |
Max. load (kg)/ position | 200*2 | 500*2 | 1000*2 | 1500*2 |
Acceleration (m/s2) | 30~1000 | 30~1000 | 30~1000 | 30~1000 |
Max. specimen size (mm) | 700*700* 700 | 1000*1000* 1000 | 1200*1200* 1200 | 1500*1500* 1500 |
Specimen installed radius (mm) | 2500 | 3000 | 6000 | 7500 |
Start time (min) | ≤5 | ≤5 | ≤8 | ≤10 |
Stop time (min) | ≤5 | ≤5 | ≤8 | ≤10 |
Continuous working time (min) | 60 | 60 | 30 | 30 |
Consumption power (kVA) | 100 | 120 | 450 | 500 |
Pit diameter (mm) | Φ7500 | Φ8500 | Φ15000 | Φ18000 |
Power connecting device | 60 conducting ring, 500V 5A | |||
Weight (kg) | 6000 | 8000 | 15000 | 30000 |
Power supply | Three-phase, 380V, 50/60Hz | |||
Measurement and control system | Computer automatic control and manual control | |||
Remark | Power connecting device and control accuracy can be configured according to related standards or customer’s requests. | |||
Environment | Temperature: 0~40℃, humidity: ≤80%, non condense |