FKQ640-6 Control system for surface mounted bop stacks
Negotiable /Piece
Min.Order:1 Piece
TOPLAND OILFIELD SUPPLIES LTD.
S/N | Name | Parameter |
1.1 | Remote control console | Size:4110(L)×2170(W)×2420(H)mm Weight:6mt |
1.2 | effective volume of oil tank | 1310L,one (1) 1〞release port and four (4) 4〞inspection port |
1.3 | triplex pump output and working pressure | 42L/min、21MPa(18.5KW,460V,60Hz) |
1.4 | air pump output× quantity | 20L/min@10.5MPa×two (2) |
1.5 | air source pressure( maxim air consumption) | 0.53~0.8 MPa (3m3/min) |
1.6 | accumulator | 40L×16=640L install by two sides with four groups symmetrically, a high pressure globe valve for each accumulator |
1.7 | usable liquid measure for accumulator | 320L |
1.8 | preliminary filling nitrogen pressure for accumulator | 6.3 MPa~7.7 MPa |
1.9 | main fold assembly | manual pressure reducing valve 0~14 MPa(2000psi),the by pass pressure is 21 MPa(3000psi) |
1.10 | ring pressure | manual & pneumatic regulator 0~18 MPa |
1.11 | controlled object quantity | one ring style, two half sealed style, one sealed style, one discharge nozzle, one standby |
1.12 | dynamo automatic start and stop controller | controlled by pressure relay, the low pressure is under 18.9MPa(2700psi), the dynamo starts; the pressure reaches 21 (3000psi) MPa, the dynamo stops |
1.13 |
| controlled by the liquid air start stop, the low pressure is under 18MPa(2600psi), it starts; the pressure reaches 21 (3000psi) MPa, it stops |
1.14 | pressure display and delivery | four 100mmOD pressure gauge show respectively: |
1.15 | pressure output interface | NPT 1″12 PCS、NPT1″1,inside and outside screw thread are available |
1.16 | pressure of the overflow valve | accumulator set overflow valve:23.1MPa(3350psi) |
1.17 | three-position four-way valve driving cylinder | seven magnetic 3″cylinder with magnetic start stop |
1.18 | solenoid valve chest | including the following elements: |
1.19 | Charger box input 110VAC,output 24VDC | including the following elements: |
2.1 | Control function | 17 explosion proof switches: fourteen are used for three-position four-way turning valve(six) and by pass valve(one); two for adjustable ring pressure; one for controlled air source |
2.2 | Rig floor | 600(L)×250(W)×750(H)(mm)、weight:50Kg |
2.3 | function | 1) four intelligent digital meter: three for the show of accumulator pressure, main fold pressure and ring pressure, one for air source pressure |
3 | Connection cable 1×50m | |
4 | pressure control | 24VDC |