Gurley Method New Energy Battery Separator Film Air Permeability Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Micro Peeling Testing Machine Lab Testing Apparatus Laser Films/ Compound Membrane
Shrikable Film Test Air Bath Oil Free Method MD/ HD Test Lab Testing Machine
ASTM Weighing Method Moisture Test Water Vapor Permeability Testing Machine Flexible Packages
Plastic Film Thickness Test ASTM & ISO Standard Lab Test Equipment Auto Sample Feeder
Vacuum Leakage Testing Machine Lab Testing Apparatus For Plastic Bottle/ Beverage Packages
Gurley Method New Energy Battery Separator Film Air Permeability Testing Machine
Product Detail
Application:
Based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Gurley Method New Energy Battery Separator Film Air Permeability Testing Machine
Features:
Ÿ Vacuum differential pressure method
Ÿ Own technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Gurley Method New Energy Battery Separator Film Air Permeability Testing Machine
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |