PZ96-E4 LED Electric Meter AC Smart Power Meter
USD $160 - $160 /Piece
Min.Order:1 Piece
Full Power Measurement Modular Design AC Energy Multi-functional Power Meter APM800
Remote High Voltage Distribution Cabinet Passive Wireless Temperature Sensor ATE400
ADW200 Din Rail 3 Phase Multi Circuit Power Meter With LoRa Wireless
Operating Thetre Insulation Monitoring Device For IT system AIM-M100
General
PZ Series electric energy meters, adopting AC sampling technology, can measure many three phase grid electrical parameters such as current, voltage, power, electric energy etc. directly or indirectly. It may be used for local display, and connected with the control equipment to form measuring and controlling system. Fitted with RS-485 communication port, adopting compatible Modbus-RTU protocol, meters can switch electric parameter signal into standard analog output, with four-channel (two-channel) switching input / two-channel switching output. Based on different requirements, by keys on the faceplate, electric parameters for transformation ratio, alarm, communication etc. can be set up and controlled. PZ series meters have extra high price performance ratio, can simply replace traditional electric transducer and measuring meters .As an advanced intelligent, digital front end acquisition component, this electric meters have widely used in various control system, SCADA system and energy source management system.
Type and specification of products
Meter type | Basic function | Shape | Optional function |
PZ72-E4/* PZ72L-E4/* | EPI/EPE,active power,reactive power,power factor measurement;Three phase current ,voltage ,frequency measurement | 1.2channel transmitting output+1 pulse+RS485communication(/MC)2.2DI2DO+1 pulse+RS485communication(/KC) | |
PZ80-E3/* PZ80-E4/* | EPI/EPE,EQL/EQC measurement; Active power,reactive power,power factor measurement; Three phase current,voltage measurement | 1.Switching4DI+1 pulse+RS485communication(/KC) 2.1channel transmitting output1+2 pulse+ RS485communication (/MC) 3.Maximum demand record(/MD) | |
PZ80L-E3/* PZ80L-E4/* | |||
PZ96-E3/* PZ96-E4/* | EPI/EPE,EQL/EQC measurement; Active power,reactive power,power factor measurement;Three phase current, voltage, frequency measurement | 1.Switching4DI+1 pulse+RS485communication(/KC) 2.Switching2DI2DO+RS485communication(/ KC) 3Switching4DI+RS485communication(/KC) 4.2channel transmitting output+2 pulse+RS485communication(/MC) 5.Maximum demand record(/MD) | |
PZ96L-E3/* PZ96L-E4/* | |||
PZ42-E3/* PZ42-E4/ | EPI/EPE,EQL/EQC measurement; Active power,reactive power,power factor measurement;Three phase current,voltage, frequency measurement | 1.Switching8DI2DO+RS485communication(/ KC) 2.Switching8DI+ 2 pulse+RS485communication(/MC) 3.2channel transmitting output+ 2 pulse+RS485communication(/MC) | |
PZ42L-E3/* PZ42L-E4/* |
Technical parameters
Technical parameters | Value | ||
Input | Connection | 3-phase-3-wire,3-phase-4-wire | |
Frequency | 45~65Hz | ||
Voltage | Rating: AC100V ,400V | ||
Overload: 1.2 fold rating( continuous );2 fold rating for 1 second | |||
Power consumption:<0.5VA | |||
Current | rating:AC 1A,5A | ||
Overload: 1.2 fold rating( continuous );10 fold rating for 1 second | |||
Power consumption:<0.2VA | |||
Output | Electric energy pulse | Output mode: open collector photocoupler pulse | |
pulse constant:10000 , 40000, 160000 imp/kWh | |||
communication | RS485,Modbus-RTU or Profibus protocol | ||
Display | LED or LCD display, set multiplying power, alarm, switching indication at will;For 1 channel analog, display related programmable setting | ||
Function | switching | input | 2channelor 4channel passive dry contact input mode |
output | Output mode:2channelrelay NO contact output | ||
contact capacity:AC 250V/1A DC 30V/1A | |||
Analog output | Output mode:1 or 4channel,0~20mA,4~20mA, programmable(Specified by the user) | ||
contact capacity:1A/30VDC 1A/250VAC | |||
accuracy class | Frequency 0.05Hz, reactive electric energy 1 class, others 0.5class | ||
Power supply | AC85~265V or DC100~350V;power consumption≤5VA | ||
Security | Power frequency withstand voltage:power supply//switching output//current input//voltage input and transmitting //communication//pulse output// switching input AC2kV 1min ; | ||
Environment | Working temperature:-10℃~+55℃; Storage temperature: -20℃~+70℃ | ||
Relative temperature: 5℃~95℃ Non-condensing; Altitude:≤2500m |
Outline and mounting cutout size
Acrel Co., Ltd. [Stock Code: 300286.SZ] is one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users.
Since June 2003, we has always been focused on the research, production and sales of intelligent electric meters. We concentrates on providing products and services to help customers improve electricity efficiency and safety. So far we had the following comprehensive solutions for different applications: 35(10)/0.4kV substation automation system, building mounted photovoltaic (BMPV) system, power quality management system, energy management system, electrical fire monitoring system, IT distribution system for medical locations, precise distribution management system, power supply monitoring system for fire protection equipment, fire emergency lighting and evacuate indicating system, fire resistant doorsets monitoring system, smart lighting control system, Lithium battery management system and electric vehicle charging system.
Certificate
Packing
Shipping
Contact Us: