Liuthum Battery Separator Film Air Permeability Testing Machine Gurley Test Battery Performance Test
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Tesion/ Modulus Of Elasticity/ Elongation Test Servo Tensile Testing Machine UTM
High Pressure Permeability Test For Materials Research Lab Gas Permeation Testing ISO+ASTM Standard
Plastic Film Permeation Test Max Gas Permeability/ High Pressure Testing Machine Lab Test Aoparatus
New Energy Lithium Battery Performance Test Gurley Method Air Permeability Testing Machine ASTM
Liuthum Battery Separator Film Air Permeability Testing Machine Gurley Test Battery Performance Test
Product Detail
Application:
Based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Liuthum Battery Separator Film Air Permeability Testing Machine Gurley Test Battery Performance Test
Features:
Ÿ Vacuum differential pressure method
Ÿ Own technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Liuthum Battery Separator Film Air Permeability Testing Machine Gurley Test Battery Performance Test
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas