Automatic Closed Cup Flash Point Tester

Automatic Closed Cup Flash Point Tester

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
10 Piece / Pieces per Month
Payment Terms:
T/T Other

Quick Details View All >

Brand Name:
GDMK
Place of Origin:
China
Model Number:
Transformer Oil Tester

Wuhan Guodian Mingke Electric Co., Ltd.

Business license
Business Type: Manufacturer
Main Products: Series resonance test device ,Transformer tester ,Circuit breaker , switch tester ,High Voltage Insulation Equipm ,Relay Protection Products ,Cable and cable fault tester ,Arrester and Insulator Test In ,SF6 Test Instrument ,Oil Testing Instrument ,DC System and Battery Test Ins ,Ground/Insulation Resistance T ,Power Energy Analyzer ,Power Energy Analyzer

Product Details

Product description:

automatic closed cup flash point tester is a kind of closed cup flash point test apparatus in accordance with unique user-defined standard for the test and uses microprocessor technology, large screen LCD display in Chinese and automatically printed test results, with high automaticity and strong capability of man-machine conversation. This apparatus possesses the features of automatic lift, automatic heating and conversion, automatic lid opening and ignition including flame ignition and electric ignition, automatic termination detection and test results printing, automatic air-cooling and overall test process. It can save and delete any test result as desired.

Automatic closed cup flash point tester

Technical index

Display mode:Large screen LCD display in Chinese

Measuring range: room temperature~300℃

Measuring accuracy: 0.1℃

Cooling system:Forced air-cooled

Operating temperature: 10~55℃

Operating humidity: 30~80%

Power: AC 220V±5%, 50Hz

Consumed power: 550VA

Overall dimension: 455×365×300(mm)

Automatic closed cup flash point tester (2)

Precautions:

1、 The level of sample shall be flush with the filling mark in the test cup.

2、 During operation, be careful not to let detection electrode on the test cup drop off.

3、 During replacing the sample, the test cup shall be cleaned and dried and the stirrer and inductive probe are also be cleaned.

4、 When ambient temperature is above the expected flash point of sample, fill the sample into the test cup and place the test cup into the cooling water for cooling down. When sample temperature is 20℃ below the expected flash point, place the sample into the apparatus for the test.

5、 After the test is finished, be sure to close the master valve of air source to avoid the air leakage.