TKGK-12FBCircuit Breaker Dynamic Analyzer
Negotiable /Piece
Min.Order:1 Piece
Wuhan Guodian Mingke Electric Co., Ltd.
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker.
Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname:High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-voltage switch characteristic test Instrument switch characteristic tester circuit breaker tester switch mechanical characteristic tester switch parameter tester Breaker Analyzer
Time measurement | 12 channels | fixed opening (closing) time |
Opening (closing) inner-phase with asynchronism | ||
Opening (closing) interphase with asynchronism | ||
Opening (closing) bounces time (and times) | ||
Testing range | 0.01ms~10000ms. | |
resolution | 1ms~100ms,0.1%±2digits | |
>100ms,0.5%±2digits | ||
velocity measurement | velocity measurement range | 1mm sensor 0.01~25.00m/s, |
0.1mm sensor 0.001~2.50m/s | ||
360 dgree angle sensor:0.01~25.00ms/s | ||
Universal sensor: 0.01~25.00ms | ||
instant opening (instant closing) velocity | ||
Appointed time slot( stroke segment or angle segment) average velocity | ||
stroke measurement | moving contact stroke (stroke) | |
contact stroke (opening) | ||
overshoot stroke or retrace (over travel) | ||
Sensor measurement range | liner sensor :50mm, resolution: 0.1mm, stroke 0.1~50mm | |
liner sensor :300mm, resolution: 0.1mm, stroke 10~300mm | ||
liner sensor :500mm, resolution: 1mm, stroke 10~500mm | ||
360 wire sensor : 360 degree,resolution:0.5 degree, stroke: 15mm~1000mm | ||
Universal sensor: 0.5 degree, stroke: 5mm~999mm | ||
current | The display current is the maximum current of the Tripping and Closing Coil current | |
Instrument power supply | AC 220V ± 10%;50Hz ± 2% | |
DC power supply | 25~265V continuous adjustment | |
current output: ≤ 20A(short time ) | ||
relative humidity | ≤90% | |
display panel | 320×240 mm LED,have adjustable contrast ratio | |
data storage | can store 50 sets of testing results | |
Printers | high speed thermosensitive printers |