Customized dc motor low voltage 1500w 48v 2500RPM
Customized dc motor low voltage 1500w 48v 2500RPM
Customized dc motor low voltage 1500w 48v 2500RPM

Customized dc motor low voltage 1500w 48v 2500RPM

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Ningbo Haofeng Magnet Technology Co., Ltd.

Business Type: Manufacturer
Main Products: Brushless DC Motor ,Brush DC Motor ,Motor Controller ,SmCo magnet

Product Details

Product Display
 

Customized dc motor low voltage 1500w 48v 2500RPM

Customized dc motor low voltage 1500w 48v 2500RPMCustomized dc motor low voltage 1500w 48v 2500RPM

Motor type Output Power Voltage Load Speed Rated Torque Efficiency Noise IP Class
KW V A RPM Nm % dB
VOL-BL3K5A72 3.5 72 51.71 1500 22.28 94 62 IP 54
VOL-BL3K5A110 3.5 110 ac 19.54 1500 22.28 94 62 IP 54
VOL-BL3K5A220 3.5 220 ac 9.77 1500 22.28 94 62 IP 54
VOL-BL3K5A380 3.5 380 ac 5.66 1500 22.28 94 62 IP 54
VOL-BL3K5B72 3.5 72 51.71 3000 11.14 94 62 IP 54
VOL-BL3K5B110 3.5 110 ac 19.54 3000 11.14 94 62 IP 54
VOL-BL3K5B220 3.5 220 ac 9.77 3000 11.14 94 62 IP 54
VOL-BL3K5B380 3.5 380 ac 5.66 3000 11.14 94 62 IP 54


 

Customized dc motor low voltage 1500w 48v 2500RPM

 

Customized dc motor low voltage 1500w 48v 2500RPM

 

VIEW MORE PLS CONTACT US >>>

 

 

Other Products

Customized dc motor low voltage 1500w 48v 2500RPM

Process Flow

Customized dc motor low voltage 1500w 48v 2500RPM 

About Us

Customized dc motor low voltage 1500w 48v 2500RPMCustomized dc motor low voltage 1500w 48v 2500RPM 

Packing&Transport

Customized dc motor low voltage 1500w 48v 2500RPM

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

 

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip. 
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

 

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator. 
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

 

      Likely cause: Controller may be defective. 
      What to do: Verify voltage is coming out of the controller.

 

Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired 
     What to do: Verify that the motor is wired correctly.

 

     Likely cause: No output power from controller. 
     What to do: Measure voltage coming from the controller.

 

     Likely cause: Motor is damaged and the armature is rubbing against the magnets. 
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

 

Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set. 
     What to do: Adjust the acceleration trim pot of the controller.

 

     Likely cause: Brushes are worn. 
     What to do: Verify brush length.

 

     Likely cause: Bearings may be defective. 
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.

 

Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring 
     What to do: Interchange the two motor leads.

 

Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator. 
     What to do: Remove burr from commutator using a commutator stone.