IEC 2HP High torque synchronous motor PMSM motor
IEC 2HP High torque synchronous motor PMSM motor
IEC 2HP High torque synchronous motor PMSM motor
IEC 2HP High torque synchronous motor PMSM motor
IEC 2HP High torque synchronous motor PMSM motor

IEC 2HP High torque synchronous motor PMSM motor

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Ningbo Haofeng Magnet Technology Co., Ltd.

Business Type: Manufacturer
Main Products: Brushless DC Motor ,Brush DC Motor ,Motor Controller ,SmCo magnet

Product Details

Product Display

IEC 2HP High torque synchronous motor PMSM motor

IEC 2HP High torque synchronous motor PMSM motorIEC 2HP High torque synchronous motor PMSM motor

 

Type Output Speed
RPM
Rated Torque
NM
Efficiency
%

Frame

Size

Mounting
KW HP B3 B5 B14
VOL-IEC63S200-2P 0.2 1/4 3000 0.64 90 63S
VOL-IEC63S200-4P 0.2 1/4 1500 1.27 90 63S
VOL-IEC71S187-6P 0.187 1/4 1000 1.78 90 71S
VOL-IEC71S375-2P 0.375 1/2 3000 1.19 90 71S
VOL-IEC71S375-4P 0.375 1/2 1500 2.38 90 71S
VOL-IEC80S375-6P 0.375 1/2 1000 3.58 90 80S

IEC 2HP High torque synchronous motor PMSM motor

IEC 2HP High torque synchronous motor PMSM motor

 

VIEW MORE PLS CONTACT US >>>

 

 

Other Products

IEC 2HP High torque synchronous motor PMSM motor

Process Flow

IEC 2HP High torque synchronous motor PMSM motor 

About Us

IEC 2HP High torque synchronous motor PMSM motorIEC 2HP High torque synchronous motor PMSM motor 

Packing&Transport

IEC 2HP High torque synchronous motor PMSM motor

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

 

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

 

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

 

      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.

 

Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.

 

     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.

 

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

 

Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.

 

     Likely cause: Brushes are worn.
     What to do: Verify brush length.

 

     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.

 

Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.

 

Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Mechanical Parts & Fabrication Services > Motor > DC Motor
Categories
Hi~