2hp 3500rpm 24v brushless electric brushless DC motor
Negotiable
Min.Order:1
Ningbo Haofeng Magnet Technology Co., Ltd.
Motor type
|
Output
|
Voltage
|
Load
|
Speed
|
Rated Torque
|
Efficiency
|
KW
|
V
|
A
|
RPM
|
N.m
|
%
|
|
VOL-BL075B48
|
0.75
|
48
|
16.98
|
3000
|
2.39
|
92
|
VOL-BL1K0C48
|
1
|
48
|
24.5
|
2500
|
3.82
|
85
|
VOL-BL1K2C24
|
1.2
|
24
|
63.3
|
4200
|
2.73
|
79
|
VOL-BL1K2C36
|
1.2
|
36
|
39.7
|
2270
|
5.05
|
84
|
VOL-BL1K5C24
|
1.5
|
24
|
73.5
|
2590
|
5.53
|
85
|
VOL-BL1K5C72
|
1.5
|
72
|
23.5
|
3200
|
4.48
|
89
|
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.