Motor type Output Power Voltage Load Speed Rated Torque Efficiency Noise IP Class
KW V A RPM Nm % dB
VOL-BL550B12 0.55 12 49.82 3000 1.75 92 62 IP 54
VOL-BL550B24 0.55 24 24.91 3000 1.75 92 62 IP 54
VOL-BL550B48 0.55 48 12.45 3000 1.75 92 62 IP 54
VOL-BL550B72 0.55 72 8.30 3000 1.75 92 62 IP 54
VOL-BL550B110 0.55 110 ac 3.14 3000 1.75 92 62 IP 54
VOL-BL550B220 0.55 220 ac 1.57 3000 1.75 92 62 IP 54

 

220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor

 

220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor

 

VIEW MORE PLS CONTACT US >>>

 

 

Other Products

220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor

Process Flow

220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor 

About Us

220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor 

Packing&Transport

220 v 24v 700w 750w 2500 w specifications electric bicycle brushless dc motor

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

 

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

 

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

 

      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.

 

Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.

 

     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.

 

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

 

Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.

 

     Likely cause: Brushes are worn.
     What to do: Verify brush length.

 

     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.

 

Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.

 

Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.