Capacity 10 ton stainless Steel Melting Furnace
Negotiable
Min.Order:1
Shanghai Fortune Electric Co., Ltd.
Capacity 25 ton Steel Melting Furnace
1. Solid steel structure and durable;
2. Good magnetic isolation, safe and reliable;
3. Solid frequency conversion power supply, easy operation; Adjustable power rate, easy operation and maintenance;
4. Easy to start up with load or free of load.
GWG--------Steel Shell Medium Frequency Coreless stainless Steel Melting Furnace
-10-----------Rated Capacity 10 Ton (10000 kg)
-6000-------Rated Power 6000 Kw
/0.5----------500 Hz (0.5 KHz)
-J------------Hydraulic tilting
Name | Unit | Parameter | Remark | |||
Furnace body: | ||||||
Model |
| GWG-10-6000/0.5J | or GW-10-6000/0.5J | |||
Rated capacity | t | 10 |
| |||
Max load capacity | t | 13 | Molten steel output | |||
Quantity of furnace body | unit | 2 | One use one standby for lining-making | |||
Two furnace body alternative change type |
| manually | change water cooling cable screw connection to capacitor bank | |||
Tilting type |
| hydraulic tilt |
| |||
Furnace body frame/shell type |
| steel shell | magnetic yoke | |||
Phase | Φ | single |
| |||
Working frequency | Hz | 500 | Center frequency | |||
Voltage of inductor | VAC | 3200~3400 | Double voltage | |||
Melting rate/speed | Iron @ 1480 oC | T/Hr | 10 | hot lining, continuous, steel earning rate≥98% | ||
Steel @ 1650 oC | T/Hr | 8 | ||||
Tap to tap time | Iron @ 1480 oC | Mins | 60~75 | |||
Steel @ 1650 oC | Mins | 75~90 | ||||
Power consumption | Iron @ 1480 oC | kw.h/t | 550 | |||
Steel @ 1650 oC | kw.h/t | 600 | ||||
Inner diameter of inductor/coil | mm | Φ1350 |
| |||
Height of inductor/coil | mm | 2000 |
| |||
Rated temperature | Iron | oC | 1480 |
| ||
steel | oC | 1650 |
| |||
Lining leakage alarm system |
| included |
| |||
Furnace over (lid) |
| excluded |
| |||
Cooling medium |
| water |
| |||
Cooling water circle type |
| closed | closed type if using closed cooling tower, Or as buyer’s request | |||
Power supply cabinet: | ||||||
Model |
| KGPS-6000-0.5S |
| |||
Type |
| KGPS | Thyristor type | |||
Rated power | kw | 6000 | 6MW | |||
Incoming voltage of MF power supply | VAC | 1000 |
| |||
Power Frequency | Hz | 50 |
| |||
Incoming current | A | 3400 |
| |||
DC Voltage | VDC | 1250 |
| |||
Rectification mode |
| 12 pulse |
| |||
Power factor | cosθ | ≥0.95 |
| |||
Starting rate | % | 100 |
| |||
Cooling medium |
| water |
| |||
Cooling water circle type |
| closed | or open type as buyer’s request | |||
Capacitor bank type |
| Open frame | not in closed cabinet | |||
Material of cooling system water pipes |
| stainless steel |
| |||
Ambient Temperature | oC | -15~+40 |
| |||
Altitude above see level (max) | meters | 1000 | Need special design if >1000m | |||
Water cooling system: | ||||||
Cooling water for furnace body | Pressure of incoming water | Mpa | 0.25~0.3 |
| ||
Temperature of incoming water | oC | 5~35 |
| |||
Temperature of outlet water | oC | ≤55 |
| |||
Flow rate | t/h | 160 | a furnace body | |||
Water temperature rise | oC | 10 |
| |||
Cooling water for power supply | Pressure of incoming water | Mpa | 0.1~0.2 |
| ||
Temperature of incoming water | oC | 5~35 |
| |||
Temperature of outlet water | oC | ≤55 |
| |||
Flow rate | t/h | 90 |
| |||
Water temperature rise | oC | 10 |
| |||
Rectification transformer: | ||||||
Rectification transformer | Capacity | KVA | 7000 | 1pc | ||
Model |
| ZSSP-7000/20 -1.0 |
| |||
Frequency | Hz | 50 |
| |||
Primary Voltage | KV | 20 or else | Provide by buyer | |||
Input connection |
| Δ | delta | |||
Secondary Voltage | V | 1000 |
| |||
Connection |
| Epitaxial triangular phase-shifting±7.5º D (+7.5º)dyn D (-7.5º)dyn |
| |||
Impedance voltage |
| 8~9% |
| |||
Phase |
| Three-phase input, six-phase output |
| |||
Voltage adjust mode |
| No excitation voltage adjust |
| |||
Cooling method |
| Force-oil and water cooling |
| |||
Cooling medium |
| 25# transformer oil |
| |||
HV Winding Material |
| copper |
| |||
LV Winding Material |
| copper |
| |||
Oil level gauge type |
| Sight class type |
| |||
Protection rating |
| hermetically sealed |
| |||
Using condition |
| outdoor |
| |||
INPUT BUSHINGS/ OUTPUT BUSHINGS |
| included |
|