Armoured Control Cable BS5308 PART1 TYPE2
Specification:
1.Voltage Rate:300/500V, 450/750V
2.Cores:Twisted Pair 1~50 pairs or Triple 1~20
3.Range of Nominal cross section:0.50 mm2 ~2.5 mm2
4.Application
It is applicable to inspection instruments connection and the signal transmission of electronic computer system, monitoring loop, automatic control system.
5.Standard:IEC60092, BS5308, TICW6-2009
6.Constructions
Conductor: Class 1/2 annealed bare copper solid or strands or Class 5 fine annealed copper wire
Insulation: PVC, XLPE, PE
Armore or Shield (optional): SWA or copper braided screen or tinned copper wire screen (individual or overall screen)
Sheath: PVC
7.Max. Operating Temperature:70°C, can be 90°C as per requirement
1.Standard
The control cable can be produced according to the standard GB9330-1988,IEC60227(60502,60332),DIN, BS, and our factory can also manufacture the cables in accordance with other standards.
2.Service Conditions
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2) The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
3.Type& Specification
Type |
Name |
Section Area(mm2) |
No. of Core |
Application Site |
KVV |
Copper Conductor,PVC Insulated and Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP |
Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP2 |
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 |
4-10 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
7-61 |
|||
10 |
4-10 |
|||
KVV22 |
Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-14 |
|||
KVVR |
Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KVVRP |
Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
|||
KYJV |
Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJVP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJV22 |
Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVP2 |
Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVR |
Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KYJVRP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
|
|
|
1.5 2.5 |
4-48 |
Installation indoors where flexibility shielding and movability are required |
More information will be offered upon your request, if needed.