Medium Voltage XLPE Insulation PVC Sheathed SWA Power Cable
Negotiable
Min.Order:1
Zhengzhou Aobest Electronic Technology Co., Ltd.
Medium Voltage XLPE Insulation PVC Sheathed SWA Power Cable
Product Description:
The XLPE insulated power cable and fire resistant cable are suitable for fixed laying in power transmission and distribution lines with A.C.50HZ and voltage rating of up to or including 6KV.
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kV 3.6/6kV.
4. PVC or PE sheathed.
5. Number of cable cores: one core (Single core),two cores(Double cores),three cores,
Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),
Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
6. Standards: Chinese national standard GB 12706 and GB 12666.6(equivalent to IEC 60502 and IEC 60331)
IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.
Application conditions:
1. The long-time permissible operation temperature of conductor shall not be higher than 70oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 160 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5. Light weight, perfect bending properties, installed and maintained easily and conveniently.
Table 1-1 Type Description & Application Occasion of cable
Type |
Description |
Application n |
|
Cu |
Al |
||
YJV |
YJLV |
XLPE insulation PVC sheath power cable |
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
YJY |
YJLY |
XLPE insulation PE sheath power cable |
|
YJV22 |
YJLV22 |
XLPE insulation, steel tape armor, PVC sheath power cable |
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
YJV23 |
YJLV23 |
XLPE insulation, steel tape armor, PE sheath power cable |
|
YJV62 |
YJLV62 |
XLPE insulation, have no the magnetism steel tape armor, PE sheath power cable |
|
YJV32 |
YJLV32 |
XLPE insulation, thin steel-wire armor, PVC sheath power cable |
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
. |
YJV72 |
YJLV72 |
XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable |
|
YJV42 |
YJLV42 |
XLPE insulation, thick steel-wire armor, PVC sheath power cable |
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint. |
Special Note |
,6272.,. The single-core magnetism material packs the cable is not suitable for to use for the AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable. Disallow the cent to cross the magnetism piping mutually when single-core cable establish, the in order to prevent results in the descent that cable transport electric current ability. |
Cable Types, Names and Application:
Cu Core |
AL Core |
Description |
Application |
VV |
VLV |
Cu(Al)Core PVC Insulated PVC Sheathed Power Cable |
For laying indoors, in ducts and tunnels, but unable to bear pulling force and pressure |
VY |
VLY |
Cu(Al)Core PVC Insulated PE Sheathed Power Cable |
|
VV22 |
VLV22 |
Cu(Al)Core PVC Insulated Steel Tape Armored PVC Sheathed Power Cable |
For laying indoors, in tunnels and directly in ground, able to bear pulling force and pressure |
VV23 |
VLV23 |
Cu(Al)Core PVC Insulated Steel Tape Armored PE Sheathed Power Cable |
|
VV32 |
VLV32 |
Cu(Al)Core PVC Insulated Fire Steel Wire Armored PVC Sheathed Power Cable |
For laying indoors, in wells and underwater, able to bear certain pulling force |
VV33 |
VLV33 |
Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Power Cable |
|
VV42 |
VLV42 |
Cu(Al)Core PVC Insulated Thick Steel Wire Armored PVC Sheathed Power Cable |
For laying in wells and underwater, able to bear certain axial pressure |
VV43 |
VLV43 |
Cu(Al)Core PVC Insulated Thick Steel Wire Armored PE Sheathed Power Cable |
|
NH-VV |
NH-VLV |
Cu(Al)Core PVC Insulated PVC Sheathed Fire Resistant Cable |
For laying indoors, in ducts and tunnels, but unable to bear pulling force and pressure |
NH-VY |
NH-VLY |
Cu(Al)Core PVC Insulated PE Sheathed Fire Resistant Cable |
|
NH-VV22 |
NH-VLV22 |
Cu(Al)Core PVC Insulated Steel Tape Armored PVC Sheathed Fire Resistant Cable |
For laying indoors, in tunnels and directly in ground, able to bear pulling force and pressure |
NH-VV23 |
NH-VLV23 |
Cu(Al)Core PVC Insulated Steel Tape Armored PE Sheathed Fire Resistant Cable |
|
NH-VV32 |
NH-VLV32 |
Cu(Al)Core PVC Insulated Fire Steel Wire Armored PVC Sheathed Fire Resistant Cable |
For laying indoors, in wells and underwater, able to bear certain pulling force |
NH-VV33 |
NH-VLV33 |
Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Fire Resistant Cable |
|
NH-VV42 |
NH-VLV42 |
Cu(Al)Core PVC Insulated Thick Steel Wire Armored PVC Sheathed Fire Resistant Cable |
For laying in wells and underwater, able to bear certain axial pressure |
NH-VV43 |
NH-VLV43 |
Cu(Al)Core PVC Insulated Thick Steel Wire Armored PE Sheathed Fire Resistant Cable |