Hot sale transmission line AAC ACSR AAAC cable
Negotiable
Min.Order:1
Zhengzhou Aobest Electronic Technology Co., Ltd.
AAAC,AAC,ACSR Bare Conductor:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
1). Standard: BS EN50182, ASTM B399, DIN48201 part6, BS 3242
2). Specification: AAAC are composed by bare concentric-lay-stranded aluminum alloy wires.
3). Application: AAAC are used in overhead electric power transmission and distribution lines.
4).Construction:
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors.
Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core.
The DC resistance at 20"C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201 J81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H 19 grade aluminum
5.Packing: Strong Wooden Drum or Iron Wooden Drum.
The data sheets below show the most common standards, British standard and IEC standard.
IEC Sizes IEC 61089
Code Number |
Stranding&wire diameter |
Approx Overall diameter |
Nominal |
Approx. |
Breaking Load |
DC Resistance at 20 |
area |
Weight |
|||||
mm |
mm |
mm 2 |
Kg/km |
KN |
Ohm/km |
|
16 |
7/1.83 |
5.49 |
18.4 |
50.4 |
5.43 |
1.7896 |
25 |
7/2.29 |
6.86 |
28.8 |
78.7 |
8.49 |
1.1453 |
40 |
7/2.89 |
8.68 |
46 |
125.9 |
13.58 |
0.7158 |
63 |
7/3.63 |
10.9 |
72.5 |
198.3 |
21.39 |
0.4545 |
100 |
19/2.78 |
13.9 |
115 |
316.3 |
33.95 |
0.2877 |
125 |
19/3.10 |
15.5 |
144 |
395.4 |
42.44 |
0.2302 |
160 |
19/3.51 |
17.6 |
184 |
506.1 |
54.32 |
0.1798 |
200 |
19/3.93 |
19.6 |
230 |
632.7 |
67.91 |
0.1439 |
250 |
19/4.39 |
22 |
288 |
790.8 |
84.88 |
0.1151 |
315 |
37/3.53 |
24.7 |
363 |
998.9 |
106.95 |
0.0916 |
400 |
37/3.98 |
27.9 |
460 |
1268.4 |
135.81 |
0.0721 |
450 |
37/4.22 |
29.6 |
518 |
1426.9 |
152.79 |
0.0641 |
500 |
37/4.45 |
31.2 |
575 |
1585.5 |
169.76 |
0.0577 |
560 |
61/3.67 |
33 |
645 |
1778.4 |
190.14 |
0.0516 |
630 |
61/3.89 |
35 |
725 |
2000.7 |
213.9 |
0.0458 |
710 |
61/4.13 |
37.2 |
817 |
2254.8 |
241.07 |
0.0407 |
800 |
61/4.38 |
39.5 |
921 |
2540.6 |
271.62 |
0.0361 |
900 |
91/3.81 |
41.8 |
1036 |
2861.1 |
305.58 |
0.0321 |
1000 |
91/4.01 |
44.1 |
1151 |
3179 |
339.53 |
0.0289 |
1120 |
91/4.25 |
46.7 |
1289 |
3560.5 |
380.27 |
0.0258 |
1250 |
91/4.49 |
49.4 |
1439 |
3973.7 |
424.41 |
0.0231 |
We also can manufacture many other specifications, if you have interest, welcome your enquiry!