BEST PRICE Medium Voltage Copper Conductor URD Power Cables
Negotiable
Min.Order:1
Zhengzhou Aobest Electronic Technology Co., Ltd.
1. Copper Conductor XLPE insulated URD Power Cable
2. Voltage: 8.7/15kV
3. Specification:
Type |
Designation |
Application |
VV |
Copper conductor ,PVC insulated ,PVC sheathed power cable |
For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct |
VLV |
Aluminium conductor ,PVC insulated ,PVC sheathed power cable |
|
VY |
Copper conductor, PVC insulated, PE sheathed power cable |
|
VLY |
Aluminium conductor ,PVC insulated ,PE sheathed power cable |
|
VV22 |
Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable |
For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force |
VLV22 |
Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable |
|
VV23 |
Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable |
|
VLV23 |
Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable |
|
VV32 |
Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable
|
For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces |
VLV32 |
Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable |
|
VV33 |
Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable |
|
VLV33 |
Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable |
|
Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied |
4. Nominal Cross-sectional Areas:
1.5 mm2 , 2.5 mm2 ,4 mm2 , 6 mm2 , 10 mm2 , 16 mm2 ,25 mm2 , 35 mm2 , 50 mm2 ,70 mm2 , 95 mm2 ,120 mm2 ,150 mm2 ,185 mm2 ,240 mm2 ,300 mm2 400 mm2 500 mm2 630 mm2 800 mm2
5. Production Range:
single core cable from 1.5 mm2 to 800 mm2,muli-core cable from 1.5 mm2 to 400 mm2
6. Operating Characteristics:
Rated power-frequency voltage u0/u:0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2
The anbient temperature under installations should not be below 0
The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter.