China top quality high voltage LXHIOLE CABLE 20KV
Negotiable
Min.Order:1
Zhengzhou Aobest Electronic Technology Co., Ltd.
LXHIOLE CABLE 20KV
China top-quality 11kv and 33kv underground cable
XLPE cable used to transmit and distribute power in power transmission and distribution system of 35kV or lower
Al/CU Conductor XLPE/PVC Insulated Thin/Thick steel armored PE Sheathed Power Cable. AL/CU,XLPE/PVC,SWA/DSTA,PVC/PE
Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.
Code name:
LXHIOV
LXHIOLE
XHIOLE
LXHIV
XHIV
XHIOV
Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-core,Three-core,Four-core,Five-core,Six-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degree.
4. D. C. Resistance of the conductor complies with the stipulations of international standar.
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable
This series includes:
Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables
-Conductor: Solid or stranded copper
-Insulation: Cross-linked polyethylene/ polyvinyl chloride ( XLPE or PVC)
-Circuit Identication: The insulation shall be red, black or other colors.
-Filler: Polypropylene with lapped binding tape
-Inner Sheath: Polyvinyl chloride (Black)
-Armor: Galvanized steel wire or double steel tape armor
-Core-covering: Binding tape
-Outer Sheath: Polyvinyl chloride/ (Black)
Type | Description | Application | |
Cu core | Al core | ||
YJV YJY | YJLV YJLY | XLPE insulated,PVC or PE sheathed power cable | For laying indoor, tunnel, channel and underground. Unable to bear external mechanical forces,but bear the traction force during laid |
YJLV22 YJV23 | YJV22 YJV23 | XLPE insulated, steel tape armored,PVC or PE sheathed power cable | For laying indoor, tunnel, channel and underground. Able to bear external mechanical forces, but unable to bear large pulling force |
YJLV32 YJLV33 | YJV32 YJV33 | XLPE insulated, fine steel wire armored, PVC or PE sheathed power cable | For laying in shaft, with large difference of level.able to bear external machinery forces and moderate pulling force. |
YJLV42 YJLV43 | YJV42 YJV43 | XLPE insulated, thick steel wire armored,PVC or PE sheathed power cable | Able to bear positive pressure and pulling force
|
We will provide you with High quality and reasonable price wire. welcome your trial order.