AMC16-DETT AC40-400V Base Station DC Energy Meter
AMC16-DETT AC40-400V Base Station DC Energy Meter
AMC16-DETT AC40-400V Base Station DC Energy Meter
AMC16-DETT AC40-400V Base Station DC Energy Meter
AMC16-DETT AC40-400V Base Station DC Energy Meter

AMC16-DETT AC40-400V Base Station DC Energy Meter

USD $70 - $70 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T L/C
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
AMC16-DETT
Operating Temperature:
-20~+60℃
Measuring Voltage Range:
AC40-400V
Measuring Current Range:
5-10000A outlet:0.25-120A

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

BRIEF INTRODUCTION 

Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations  where have sharing requirements, and switch power supply is without the function of sub-user  metering. The meter could measure 6 circuits DC energy, and supply working current to the  matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.  have the functions of telemetering,teleindication,teleadjusting, metering at real time, energy  quality abnormal alarm, data storage and processing, data interaction. This meter can measure  DC power consumption of three operators, providing detail datas for base station.


MODEL

Name

Model

Installation

Base station DC energy meter

AMC16-DETT

35mm din rail


SPECIFICATIONS

Input

DC voltage

1 channel: -48VDC

DC current

6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V.

Commercial power monitoring

1 channel: 0-5VDC

Overload capacity

Voltage:1.2times continued,2 times continued 1s;

Current: 1.2 times continued,10 times continued 1s.

Accuracy (superposition hall sensors)

1%In≤I≤10%In error±2.5%; I>10%In error±2%

Measurement resolution

Voltage output accuracy 0.01V; current output accuracy 0.01A;

power output accuracy 0.01kw; energy output accuracy 0.01kwh

Functions

Basic function

Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;485 communication

Metering function

Start current: under rated voltage, when the load current value of
the meter doesn’t exceed 1% of the max. current, the meter starts.
Shunt running current: when there is no current in the current
circuit of the meter, and 85%-125%of the rated voltage is applied
on the voltage circuit, the calculator shall not have more than one digital change

Alarm function

DC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm, AC input power failure alarm

Timing function

support broadcast timing, could remote timing to the meter by RS485

Communication

Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.
Communication protocol: standard or custmized

Hall sensor power supply

:Power supply output:+12V/100Ma, -12V/50mA

Clock accuracy

≤0.5s/d(23)≤1s/d(-20℃~60)

Auxiliary power supply

Voltage range

-40V~-60VDC

Power consumption

Whole device≤2W(no hall power supply output)


DIMENSION


Installation and Wirings

RECOMMEND HALL SENSOR





Acrel split core hall current transducer / mini transmitter AHKC-K Input 0-2000A

Acrel Co., Ltd. [Stock Code: 300286.SZ] is one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users.


Since June 2003, we has always been focused on the research, production and sales of intelligent electric meters. We concentrates on providing products and services to help customers improve electricity efficiency and safety. So far we had the following comprehensive solutions for different applications: 35(10)/0.4kV substation automation system, building mounted photovoltaic (BMPV) system, power quality management system, energy management system, electrical fire monitoring system, IT distribution system for medical locations, precise distribution management system, power supply monitoring system for fire protection equipment, fire emergency lighting and evacuate indicating system, fire resistant doorsets monitoring system, smart lighting control system, Lithium battery management system and electric vehicle charging system. 


Acrel split core hall current transducer / mini transmitter AHKC-K Input 0-2000A


Certificate

Acrel split core hall current transducer / mini transmitter AHKC-K Input 0-2000A

Acrel split core hall current transducer / mini transmitter AHKC-K Input 0-2000A

 

Acrel split core hall current transducer / mini transmitter AHKC-K Input 0-2000A

 

Packing

Shipping

Contact Us:




Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Power Meters
Categories
Hi~