Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price
Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price
Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price
Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price
Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price
Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price

Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price

USD $5,800 - $36,000 /Set

Min.Order:1 Set

Supply Ability:
30 Set / Sets per Month
Port:
shenzhen
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
HAIDA
Place of Origin:
Guangdong, China

Dongguan Haida Equipment Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: Battery Test Machine ,Tensile Testing Machine ,Environmental Testing Machine ,Furniture Testing Equipment Series

Product Details

    Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price

 Automatic sampling gas chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.

                Insulated Gas Chromatographic Analyser/Gas Chromatography Analyser Price

Application industry

1. Analysis of dissolved gas in transformer oil;

2. Analysis of ethylene oxide in medical devices.

3. Analysis of coke oven gas;

4. Pesticide residue analysis;

Alcohol analysis in blood; 5.

6. Analysis of natural gas and liquefied gas;

7. Indoor environment TVOC analysis;

8. Analysis of liquor components;

9. High purity gas analysis;

10. Detection of solvent residue of packaging materials.

 

Performance characteristics

1. Inlet flow rate, chromatographic column load airflow, detector gas flow, complete EPC control

Micro-channel Air Circuit Integrated Board

All-imported miniature proportional valves and flow/pressure sensors Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi

2. Industry-Leading detector design

All detectors are high-precision electronic flow/pressure control

Fit and fill column and capillary column Special ceramic treatment of the enlarged plate, in the humid season is always stable Automatic ignition, hydrogen leak automatic protection function, safe and reliable

3. Automatic ignition, hydrogen leakage automatic protection function, safe and reliable

4. Accurate furnace temperature tracking design

5. Independent Heating small column box In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.

6. Fully imported Valve configuration system Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;

7. Precision temperature control of the heating furnace Furnace internal control accuracy less than 0.01°c

    The temperature difference between the internal points is not more than the °c

   Rapid heating and cooling, the highest program heating speed: 120℃/min, balance time 10 seconds, cooling            time 300°c~50°c 6 minutes Absolute control of the temperature accuracy (with the actual temperature difference is less     than 0.3C)

8. Pneumatic cutting technology for the convenience of implementation

     Multi-dimensional chromatographic function to complete the separation and analysis of complex samples It     can realize the inverse blowing function of chromatographic column to save the analysis time and cycle            greatly.

9. Advanced Power Distribution Management shunt A 3000 watt UPS can provide 10 units of normal power          2250 watts/set of GC stable working power supply

10. Automatic Feed 8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

11. With Automatic online detection function

 

Technical indicators

Column temperature Box

Furnace Size

28×30×18cm

Temperature control Range

Above room temperature5℃~450℃;Using liquid nitrogen cold traps:-80~400℃;Using dry ice traps:-55~400

Temperature setting accuracy

0.1℃

Maximum program heating rate

120℃/min

Maximum once method run time

999.99min

Program heating order number

7

Program heating rate

0.1~120℃/min(Incremental 0.1℃)

Operation Column loss compensation (dual channel)

Heating Zone

6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature )

 

300℃

Detectors

Hydrogen Flame Ionization detector FID

Maximum operating temperature

450℃

Minimum detectable limit

2.5pgC/s [n-C16]

Dynamic linear range

10710%)

Data acquisition frequency

The highest: 100Hz

Thermal conductivity cell detector  TCD

Maximum operating temperature

400℃

Minimum detectable limit

<400pg C3H8/ml(He)

Dynamic linear range

1055%)

data acquisition frequency

The highest: 100Hz

Flame photometric detector  FPD

Maximum operating temperature

250℃

Minimum detectable limit

<4pgC/sec,<1pg P/sec

Selective

105gS/gC,106gP/gC

Dynamic linear Range

>103S,>104P

Electronic Capture Detector ECD

Maximum operating temperature

400℃

Detector compensation Gas Type

5% Methane/Argon or nitrogen

Minimum detectable limit

<0.01Ppg/s lindane

Dynamic linear range

>5×1055

data acquisition frequency

100Hz

Radioactive sources

<12mCi  63Ni

Nitrogen and phosphorus detectors NPD

Maximum operating temperature

450℃

Minimum check out limit

<0.2 pg N/sec,<0.2 pg P/sec

Dynamic linear Range

105N,105P

Minimum detection limit

<0.3pg C/Sec

The above detectors are suitable for filling column and capillary column

Optional configuration

Anti-control software

Automatic Feed b6891n

 