vlf test equipment hipot test kit 0.1hz cable ac hipot withstand voltage test system
USD $1,000 - $5,000 /Piece
Min.Order:1 Piece
Wuhan Sansion Power Equipment Manufacturing Co., Ltd.
Withstand and Leakage Current Test Electric DC Hipot High Voltage Generator 120kv DC Hipot Tester
200kV 5mA DC Hipot Tester good sales 40kv High Voltage Generator
Automatic Insulation Rubber Material Boots & Gloves Withstand Voltage Test System
Automatic Electrical Insulating Boots Gloves Withstand Voltage Test Machine
50kV Hipot For Field Testing Rubber Insulating Gloves and Boots Withstand Voltage
General Information:
VLF Test Sets from 30kV - 90kV with Sine Wave Output
VLF means 'Very Low Frequency' is used in AC hipot test for power cables, transformers, switchgear and other electrical apparatus.
A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.
Features:
√ Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
√ Portable, easy to move.
√ Large LCD can display waveform clearly, and test report can be printed by built-in printer.
√ The data of current, voltage, and waveform can be sampled at HV side.
√ Over voltage protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.
√ Over current protection: high & low voltage double protection, the precision value of power off protection can be setting at HV side. When the current of LV side is exceeded rated, the control unit will shut itself down within 20ms.
√ HV output protection resistor is built in the booster, not need to connect outside resistor.
√ Adapting high & low voltage closed loop negative feedback control circuit, there is no capacitive rise effect during the output.
Specifications:
√ Accuracy: 3%
√ Voltage +/- peak value error: ≤3%
√ Voltage waveform distortion: ≤5%
√ Working temperature: -10ºC+40ºC
√ Working humidity: ≤85%RH
Model |
Output Voltage/Current |
Load Capacity |
Fuse |
Control Unit |
Booster |
||
Net Dim. |
Net Wt |
Net Dim. |
Net Wt |
||||
SXVLF-30/1.1 |
30KV/29mA |
0.1Hz ≤ 1.1uF |
8A |
28×37×22 |
4 |
33×18×34 |
25 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-40/1.1 |
40KV/29mA |
0.1Hz ≤ 1.1uF |
|
28×37×22 |
4 |
35×20×36 |
45 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-50/1.1 |
50KV/59mA |
0.1Hz ≤ 1.1uF |
|
28×37×22 |
4 |
37×24×39 |
45 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-60/0.5 |
60KV/59mA |
0.1Hz ≤ 0.5uF |
|
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz ≤ 1.0uF |
|||||||
0.02Hz ≤ 2.5uF |
|||||||
SXVLF-70/0.5 |
70KV/59mA |
0.1 Hz, ≤0.5µF |
|
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
|||||||
SXVLF-80/0.5 |
80KV/59mA |
0.1 Hz, ≤0.5µF |
20A |
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
|||||||
SXVLF-90/0.5 |
90KV/59mA |
0.1 Hz, ≤0.5µF |
|
28×37×22 |
4 |
33×20×35 |
30+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |