Transformer load and no-load loss characteristics tester no load losses test of power transformer
USD $1,000 - $5,000 /Piece
Min.Order:1 Piece
Wuhan Sansion Power Equipment Manufacturing Co., Ltd.
Transformer No Load Losses Test Set Empty Load Loss Test Equipment
China Manufacturer Lab Equipment Automatic Transformer Comprehensive Characteristics Test Bench
China Manufacturer High Voltage 12kV Capacitance Tan Delta Tester for Transformer
12kv C&Df Tester Transformer Tan Delta Capacitance and Dissipation Factor Tester
Transformer On Load Switch Tap Changer Characteristics Tester for transformer
General Information:
100% accuracy, SXBTC Transformer Capacity & Loss Tester is 4 in 1, that is transformer capacity tester, transformer loss parameter tester, harmonic analyzer and oscilloscope. SXBTC can test various transformers on capacity, no-load current, no-load loss, short circuit loss, impedance voltage and a range of power frequency parameters. It also can measure the voltage of no-load test, current distortion factor, harmonic content, and vector analysis.
Also called: Transformer Iron & Copper Loss Tester/Transformer load/no-load Tester)
Standard: IEC270
Specifications:
Active: | Voltage measuring range: 0~10V |
| Current measuring range: 0~10A |
Passive: | Voltage measuring range: 0~750V |
| Current measuring range: 0~100A range switching fully automatically. |
Precision: | Voltage:±0.2% |
| Current:±0.5% |
| Power:±0.5%(CosΦ>0.2),±1.0%(0.02
|
Working Temperature: | -10ºC~ +40ºC |
Charging source: | AC 160V~260V |
Insulation: | Insulation resistance of voltage, current input terminal to the shell ≥100M. |
The affordable power frequency between power source and shell: 2kV (effective value), takes 1 minute test. |
Features:
√ To measure the capacity of all kinds of distribution transformer, passive measure, safely and accurately.
√ Built-in power source, auto supply three phase highpower test source and only needs to be recharged every 500 transformers testing.
√ No need to connect three phase power source, or regulator or any other accessories when do the test on transformer capacity and short circuit loss. To simplify the connection, and improve the efficiency greatly.
√ Can test no-load current, no-load loss, short circuit voltage, short circuit loss of all kinds of transformer.
√ Auto waveform distortion correction, temperature correction (provide simple temperature correction and additional loss separately), voltage correction (no-load test under non rated voltage), current correction (short circuit test under non rated current). The test results are more accurate.
√ Measure harmonic content and total harmonic distortion of voltage and current.
√ Simple vector analyzing, drawing vector diagram.
√ To display oscillogram of all electric parameter wave, as for oscilloscope usage.
√ Max. voltage measuring range can reach to 750V.
√ Capacity measuring range: 20kVA~100000kVA.
√ Large high brightness LCD screen.
√ Built-in panel-type thermal printer, fast print test results.
√ 20 groups parameter can be pre set. The set parameter can be deleted at any time.
√ 200 groups capacity test results can be stored up.
√ Finish full current load test under 1000kVA below distribution transformer.
√ Finish 2500kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.)
√ All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, Non rated voltage correction and non rated current correction. The test results are more accurate.
√ Real-time clock, recording test date automatically, suitable for storage and management of test results.
Wuhan Sansion Power Equipment Manufacturing Co., Ltd. is a modern company focusing on design and manufacturing of test and measurement instruments. Our company covers 5,000 square meters with 120 employees.
Sansion has more than 20 years’ experience of producing electrical test sets and solutions for transformers, circuit breakers, CT/PT, relay protection, cable and electric power systems to test and calibration equipment.
Sansion has obtained ISO 9001 quality certificate and all of our products are in conformity with the international standards.
With superior quality, reasonable price and perfect after-sales service, we are aiming to expand the markets in all countries of the world. We look forward to working with you.
OUR ADVANTAGES:
1. QUALITY
As an ISO and SGS certified company.
2. Sales Market
We are exporting to 52 countries worldwide.
3. Technical capacity
We have 26 engineers. 6 engineers are doctor’s degree. Who have 26years working experience . 8 engineers are master’s degree.
4. After-sales Service
Warranty period is one year. Engineers available to service the equipment.
Our Service:
Welcome your enquiry
Welcome to contact us for more details
Sansion Power Electric Co.,LTD
Sales Manager :Ms Ying
Tel:+86-13657220727
Skype:sansionpower
Wechat:sansionpower