404SXV Micro Vickers hardness tester With Dual Indenter
404SXV Micro Vickers hardness tester With Dual Indenter
404SXV Micro Vickers hardness tester With Dual Indenter
404SXV Micro Vickers hardness tester With Dual Indenter
404SXV Micro Vickers hardness tester With Dual Indenter
404SXV Micro Vickers hardness tester With Dual Indenter

404SXV Micro Vickers hardness tester With Dual Indenter

USD $1,000 - $5,000 /Set

Min.Order:1 Set

Supply Ability:
55 Set / Sets per Month
Port:
qingdao
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
PTE
Place of Origin:
Shandong, China
Model Number:
404SXV
Power:
Electronic
Usage:
Hardness Tester

Jinan Precision Testing Equipment Co., Ltd.

Business Type: Government ministry/Bureau/Commission
Main Products: Hydraulic Universal Testing Machine ,Compression Testing Machine ,Geotextile Tensile Testing Machine

Product Details

404SXV Micro Vickers hardness tester With Dual Indenter

404SXV Micro Vickers hardness tester With Dual Indenter

 

 

 

Product Description

 

Applications:

 

1The Micro Vickers and Knoop hardness tester is a new-type hardness testing instrument adopting the precision mechanism and photoelectric computer software. The instrument can be used to test the Vickers or Knoop hardness. The hardness is calculated out with tested value of diagonal to be input into the unified computer.

2The Micro Vickers and Knoop Hardness Tester is used for the testing of the metallic materials such as the small components, the thin plates, the metallic foil, the fine-quality electric cables, the thin hardness layers the electroplated layers as well as the non-metallic materials that cannot be tested with a great test force, such as the glass, the jewelries and the ceramics. It is particularly important that the tester can be used to the internal hardness of the induction hardened or carburized materials according to the metallic structure.

3The hardness testing is divided into two parts: the first part, using the known test force to drive the diamond indenter into the surface of the material to be tested; the second part, the client has measured the length of the diagonal of the indentation, and input the data into the main computer, which will calculate out the Vickers hardness value or the Knoop hardness value.

4The difference between the Vickers and Knoop hardness test lies in the use of the different indenters. The Vickers indenter is a pyramid-shaped indenter with a square bottom while the Knoop indenter is a pyramid-shaped indenter with a rhombus-shaped bottom. Besides the Vickers test should measure two diagonals whereas the Knoop hardness test needs to measure only one diagonal.

  Technical Specifications

1. Testing scales:

Vickers Scales: HV0.01, HV0.025, HV0.05, HV0.1, HV0.2, HV0.3, HV0.5, HV1

 (Knoop Scales: HK0.01, HK0.025, HK0.05, HK0.1, HK0.2, HK0.3, HK0.5, HK1)

2. Units of the test forces: gf,mN

3. Test forces:  (gf)  10, 25, 50, 100, 200, 300, 500, 1000(1K)

               (m N)  98, 245, 490, 980, 1960, 2940, 4900, 9800

 Attention: The present hardness tester may have the optional specially–made a set of weights (to be provided according to the contract) for the test of the Vickers hardness with the 2000gf (19610 m N) test force.

4. Selection of the test force: Turn the test force changing hand wheel. The chosen test force will be shown on the screen.

5. Carriage-loading control: Automatic (loading/dwell/unloading)

6. Dwell time: 0-95 seconds (5 seconds as the increase amount)

7. Test mode: HV/HK

8. Hardness value: Measure the indentation by hand, and the measurement reading will be input automatically. The calculation and the indication of the hardness value are automatic.

9. Language: English

10. Optical system

Objectives

10×(observation)

20×(measurement)

40×(measurement)

Lateral Microscopes

10×

Total Amplifications

100×(observation)

200×(measurement)

400×(measurement)

Max. Measurement Field

 

400μm

200μm

Resolving power

 

0.03μm

0.015μm

 

11. X-Y Testing Table

Dimension: 100×100mm

Travel: 25×25 mm

Resolving Power: 0.01mm

12. Specimen

    The Maximum Height: 90mm

    The Maximum Depth: 120mm (measured form the center)

13. Energy-saving mode: After 10 minutes of non-use it enters the repose mode automatically.

14. Light Source: 12V/20W

15. Illumination of the light source: Several grades, adjustable

16. Power source: 220V, 50/60Hz

17. Dimension of the instrument: 495×305×550mm

18. Weight of the instrument: About 33kg

 

 

 

more products:

WAW-C Hydraulic unviersal testing machine

 

ModelWE-100C
Max. Testing Load (kN)100

Load range(kN) and Min
Scale (kN/div)

0-20/0.05
0-50/0.1
0-100/0.2

Max. tensile space
(Including piston Travel) mm

560

Max. Compression space
(mm)

530

Max. Distance Between Two
Fulcrums of Bending Test
(mm)

400

 

-------------------------------------------------------------------------------------------------------------------------------------------------------

Compressive strength testing machine for concrete

 

ModelYES-1000
Load display accuracy±1%

Distance between upper
and lower platen

320mm
Diameter of lower platen300 mm
Piston stroke30mm
Pump nominated pressure40MPa

 

-------------------------------------------------------------------------------------------------------------------------------------------------------

Fiber strength testing machine (single column): 

ModelWDW-E1,E2, E3, E5, E10, E20, E30, E50, E100
Max. Load1kN,2kN,3kN,5kN,10kN,20kN
Deformation accuracy≤±0.5%
Load speed0.005-500mm/min
Total crosshead travel (mm)1075
Spacing of grip to grip(mm)750

 

-------------------------------------------------------------------------------------------------------------------------------------------------------

PLG 300C PC Control High Frequency Fatigue Testing Machine

ModelPLG-10C  PLG-20C PLG-50C PLG-100C PLG-200C  PLG-300C
Mean load max(kN)±10 ....
 Load step1,2,5
Accuracy of static load ≤±1%
Range of frequency(Hz) 60~300HZ
  Power 380V, 3phs,

 

-------------------------------------------------------------------------------------------------------------------------

WAW Computer Control Servo Hydraulic Universal Testing Machine

  Model  WAW-300E  WAW-600E  WAW-1000E  WAW-2000E
  Max. Testing Load (kN)  300 ....
  Load Accuracy  ≤±1% from 2% to 100% of full scale
  Strain accuracy  ≤±0.5%
  Load frame Type  4-column and 2-screw structure
 

Max. tensile space (Including piston
Travel) mm

  690

 

-------------------------------------------------------------------------------------------------------------------------------------------------------

TORSION TESTING MACHINE

  Item   NJS-30
  Max torque(Nm)  30
  Torque resolution (Nm)  0.01
  Accurate measuring range of torsion (Nm)  0.6-30
  Full-scale reading of torsion angle (º)  9999.9
  Torsion angle resolution (º)  0.01

 

-------------------------------------------------------------------------------------------------------------------------------------------------------

PLS Dyanmic testing machine

 

 Model  PLS-50
 Static  ±50
 Dynamic  50
 Function generator

 Range of frequency(Hz)

  0.01~20HZ
 Stroke of piston(mm)  ±75
 

 Distance between columns
(mm)

  500

 

RTH CREEP TESTING MACHINE

 

Working Temp. range400°C~1200°C
  Length of effective soaking zone  150mm
  Furnace pipe:  φ90mm
  Furnace:  φ300mm
  Furnace life:  ≥3000hours
   Timing error  ±0.2%

 