AOYI Single Phase DC Solid State Relay 40A 10A 25A
USD $9.5 - $10 /Piece
Min.Order:1 Piece
Wenzhou Xiaohai Import And Export Co., Ltd
Load Current | 10A,25A,40A,60A,75A,90A |
Load Voltage | 90-480VAC |
Control Voltage | 4-32VDC |
Control Current | DC6-12mA |
On Voltage | ≤1.5v |
On leakage Current | ≤4mA |
On-off time | ≤10mS |
Dielectric Strength | 2000VAC |
Insulation Resistance | 500MΩ/500VDC |
Ambient Temperature | -20~+70℃ |
Mounting Method | Bolt Fixing |
Working Station Indicator | LED |
Weight | 110g |
1. Resistive load could not exceed 60% of the rated current.
2. Inductive or capacitive load could not exceed 40% of the rated current.
3. Electric machine load could not exceed 20% of the rated current.
4. Proper radiator adapted to the working requirement of solid state relay should be equipped, the allowance should be widened
when the load radiating condition is not so good. Short-circuit load is not allowable.
5. Over current protection: over current and short circuit are the main reasons for permanent damage of output controllable silicon
in the SSR, and using fast fuse and air switch is one of methods for over current protection, fuse is also available for small capacity.
6. Over voltage protection: It can adopt parallel voltage-dependent resistance(MOV), the MOV area decides the absorption power,
while its thickness decides the protective voltage value, generally, 471/10D voltage-dependent resistance for 220V series SSR,
681/10D voltage-dependent resistance for 380V series SSR, 821/10D voltage-dependent resistance for 480V series SSR.
SSR serious solid state relay flame resistant engineering plastic case, epoxy resin encapsulation, screw thread educing terminal
connection with high strength structure, impulse resistance, high shock resistance performance, small driving current for input terminal
and convenient connection with computer terminal and digital control circuit, the product is widely used in automation control fields
such as petroleum, chemical industry, instrument and meter, pharmacy machine, food machine, packaging machine, textile machine,
plastics machine, numerical control lathe, entertainment facility, etc., especially for severe environment full of corrosion, moisture and
dustproof or requiring explosion-proof unfavorable conditions or switching on-off frequently conditions.
Please confirm the practical working voltage load power and control method before selecting, make sure that the load current does not exceed the allowance of SSR.
Single Phase: Resistive load power (KW) *9=Ampere of SSR
For example: suppose the resistive load power is 3KW,we should select the SSR Ampere ›27A