Coating Thickness Gauge TBT-TT4100 & TBT-TT3100

Coating Thickness Gauge TBT-TT4100 & TBT-TT3100

USD $230 - $300 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Port:
China Shanghai OR Nanjing Seaport
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
TBT
Place of Origin:
Jiangsu, China
Model Number:
TBT-TT4100 & TBT-TT3100

Nanjing T-Bota Scietech Instruments & Equipment Co., Ltd.

Business Type: Trading Company
Main Products: Concrete testing machine ,Soil testing machine ,Material testing machine

Product Details

Coating Thickness Gauge

 

I. Measuring Principle

The instrument adopts the magnetic and eddy current principle to measure in a non-destructive way

 

(1) Magnetic way (type F probe)

 

measure the thickness of non-magnetic coatings on magnetic metallic base (e.g. zinc, aluminum, Cr. Copper, rubber, paint, coating on the base of steel, iron, alloy and hard magnetic steel etc.)

 

 (2) eddy current way (type N probe)

 

measure all electrically insulating coating layers, such as lacquer, Varnish, paint, anodizing coating on nonferrous metals, also on austenitic VA steel materials.

 

II. Technical Parameter:

List 1 of technical parameters

Type F probe :

Probe 

F400 

F1 

F1/90°

F10 

Measuring Principle 

Magnetic method

Measuring range(mm) 

0~400

0~1250

0~10000

Min resolution(mm)

0.1

0.1

10

Tolerance

One-point calibration (mm)

±(2%H+0.7)

±(2%H+1)

±(2%H+10)

Two-point calibration (mm)

±(1%H+0.7)

±((1%H+1)

±(1%H+10)

Minimum radius of curvature (convex) (mm)

1

1.5

flat

10

 Minimum measuring area(mm)

F3

F7

F7

F40

Minimum thickness of base material(mm)

0.2

0.5

0.5

2

Type N probe :

Probe

N400

N1

CN02

Measuring Principle

Eddy current method

 Measuring range (mm)

0~400

0~1250

10~200

 Min resolution(mm)

0.1

0.1

1

Tolerance

 One-point calibration (mm)

±(2%H+0.7)

±(2%H+1.5)

±(2%H+1)

 Two-point calibration (mm)

±(1%H+0.7)

±(1%H+1.5)

--------

Minimum radius of curvature (convex) (mm)

1.5

3

flat

Minimum measuring area(mm)

F4

F5

F7

Minimum thickness of base material(mm)

0.3

0.3

0

Note: H——Measured Value

 

III. Standard Configuration

main frame                 1

Substrate                    1

Calibration   foil           5

9V BaMTery                 1

Probe F1/N1                1

Manual  Instruction     1