Drawell 4 Channel Plates Strip Tube 0.1ml Test Kit Machine Gradient Real Time PCR
USD $15,000 - $20,000 /Unit
Min.Order:1 Unit
Chongqing Drawell Instrument Co., Ltd.
TC1000-S Laboratory PCR Thermal Gradient Cycler Instrument Real Time PCR Test Machine
Gentier 96R Factory Price Laboratory 4 Channel Real Time Quantitative PCR Test Machine
High Quality Integrated Automatic Chemiluminescence Immunoassay Analyzer
96X0.2mL PCR tube 8X12 PCR plate or 96 well plate PCR Thermal Cycler
Professional Auto Chemiluminescence Detector Immunoassay System Analyzer
RT-PCR Gentier 96R
PECIFICATION
Gentier 48E |
Gentier 48S |
Gentier 48R |
Gentier 96E |
Gentier 96S |
Gentier 96R |
Gentier 96C |
|
Thermal Block |
|||||||
Sample capacity(wells) |
48
|
96
|
|||||
Reaction Volume |
5-100 pL |
0-100 pL
|
|||||
Consumables |
0.2ml 8-strip tubes ,0.2ml PCR single tube(Optical flat cap,clear tube) |
0.2ml 96-well Plates |
(unskirt) ; 0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap,clear,frosted,white tube) |
||||
Temperature range |
0°C-100°C
|
0°C-100°C
|
|||||
Heating/cooling method |
Peltier |
Peltier
|
|||||
Max heating rate |
8.0°C/sec
|
6.1°C/sec
|
|||||
Average heating rate |
6.0°C/sec
|
4.5°C/sec
|
|||||
Max cooling rate |
5.5°C/sec
|
5.0°C/sec
|
|||||
Average cooling rate |
4.0°C/sec
|
2.8°C/sec
|
|||||
Temperature accuracy |
±0.1 °C
|
±0.1 °C
|
|||||
Temperature uniformity |
±0.1 °C
|
±0.1 °C
|
|||||
Gradient Range |
1°C-40°C |
N/A |
1°C-40°C |
1°C-40°C |
N/A |
1°C-40°C |
N/A |
Gradient block |
8 row |
|
8 row |
12 row |
|
12 row |
|
Special temperature protocol |
Gradient PCRXong PCR,Touch Down PCR |
Long PCR.Touch Down PCR |
Gradient PCRzLong PCR,Touch Down PCR |
Gradient PCR,Long PCRlbuch Down PCR |
Long PCR,Touch Down PCR |
Gradient PCR,Long PCRlbuch Down PCR |
Long PCR,Touch Down PCR |
Heat Lid |
|||||||
Temperature range |
|
Room Temperature-110°C |
|
|
Room Temperature-110°C |
|
|
Optical System |
|||||||
Excitation Source |
4LEDs |
2LEDs |
6LEDs |
4LEDs |
|||
Detector |
|
Photodiode |
|
|
Photodiode |
|
|
Detection Position |
|
Excitation and scan from lateral |
|
|
Excitation and scan at top |
|
|
Detection method |
4 channels scanning at the same time, no edge effect. |
|
6 channels scanning at the |
same time, no edge effect. |
|
||
Detection time |
|
2 seconds for 48 wells for all channels |
|
|
7 seconds for 96 wells for all channels |
|
|
Range of excitation/ emission wavelengths(nm) |
1 465 /510 (FAM,SYBR Green l,SYTO9,EvaGreen,LC Green) 2 527/ 563 (HEX,VIC,TET,JOE) 3 580 /616(ROX,Texas Red) 4 632/ 664( Cy5) |
1 465 /510(FAM,SYBR Green I.SYTO9, EvaGreen,LC Green) 2 527/ 563 (HEX,VIC,TET,JOE) |
1.465 /510(FAM,SYBR Green l,SYTO9,EvaGreen,LC Green) 2.527/ 563 (HEX,VIC,TET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664( Cy5) 5.680 /730 (Alexa Fluor680) 6.465 /616 (FRET) |
1.465 /510(FAM,SYBR Green l,SYTO9,EvaGreen,LC Green) 2.527/ 563 (HEX,VIC JET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664( Cy5) |
|||
Probe |
Taqman ProbezMolecular beacons probe, Scorpion probe |
Taqman Probe,Molecular beacons probe,Scorpion probe ,FRET |
Taqman Probe,Molecular beacons probe,Scorpion probe |
||||
Multiplexing |
Up to 4 targets |
Up to 2 targets |
Up to 6 targets |
Up to 4 targets |
|||
Fluorescence Linearity |
|
r>0.990 |
|
|
rs0.990 |
|
|
Fluorescence Dynamic Range |
|
Adjustable |
|
|
Adjustable |
|