RT PCR Machine Price
USD $9,999 - $12,999 /Piece
Min.Order:1 Piece
Shanghai Drawell Scientific Instrument Co., Ltd.
Real-Time Quantitative PCR | |||
Gentier 48E | Gentier 48S | Gentier 48R | |
Thermal Block | |||
Sample capacity(wells) | 48 | ||
Reaction Volume | 5-100 μL | ||
Consumables | 0.2ml 8-strip tubes ,0.2ml PCR single tube(Optical flat cap,clear tube) | ||
Temperature range | 0°C-100°C | ||
Heating/cooling method | Peltier | ||
Max heating rate | 8.0°C/sec | ||
Average heating rate | 6.2°C/sec | ||
Max cooling rate | 6.2°C/sec | ||
Average cooling rate | 4.5°C/sec | ||
Temperature accuracy | ±0.1℃ | ||
Temperature uniformity | ±0.2℃ | ||
Gradient Range | 1°C-40°C | N/A | 1°C-40°C |
Gradient block | 8 row | 8 row | |
Special temperature portocol | Gradient PCR,Long PCR,Touch Down PCR | Long PCR,Touch Down PCR | Gradient PCR,Long PCR,Touch Down PCR |
Heat Lid | |||
Temperature range | Room Temperature–110°C | ||
Optical System | |||
Excitation Source | 4LEDs | 2LEDs | |
Detector | Photodiode | ||
Detection Position | Excitation and scan from lateral | ||
Detection method | 4 channels scanning at the same time, no edge effect. | ||
Detection time | 2 seconds for 48 wells for all channels | ||
Range of excitation/ emission wavelengths (nm) |
1 465 /510 (FAM,SYBR Green I,SYTO9,EvaGreen,LC Green) 2 527/ 563 (HEX,VIC,TET,JOE) 3 580 /616 (ROX,Texas Red) 4 632/ 664( Cy5) |
1 465 /510 (FAM,SYBR Green I,SYTO9,EvaGreen,LC Green) 2 527/ 563 (HEX,VIC,TET,JOE) |
|
Probe | Taqman Probe,Molecular beacons probe,Scorpion probe | ||
Multiplexing | Up to 4 targets | Up to 2 targets | |
Fluorescence Linearity | r≥0.990 | ||
Fluorescence Dynamic Range | Adjustable | ||
Performance | |||
Sample Linearity | /r/≥0.999 | ||
Sample repeatability | Ct value CV≤0.5% | ||
Sample Dynamic Range | 1-1010 copies | ||
Software Funtions | |||
Data Analysis modes | Qualitative analysis,Absolute quantification, Relative quantification,Genotyping analysis,Endpoint analysis, Melt curve analysis, High Resolution Melting |
||
Control modes | 1.7 touch screen 2. PC direct control 3. WLAN control(One PC can control max 10 units, and device can be controled by any PC in the WLAN) |
||
Data Stroage | Upload and download through USB disk,1000 results can be stored in machine | ||
Power failure protection | Automaticly start running experiments after power supply, no need wait PC software | ||
Customize Report | Templetes reserved ,report can customized | ||
Administration Management | Administrator can set funtions limts for users | ||
Fault Management | Fault report and analysis, solution instruction | ||
LIS connection | CSV,Excel,TXT format data output,open port for LIS connection | ||
Others | |||
PC operating system | Win 7, Win 10 | ||
Communication Port | 1 ethernet and 2 USB | ||
Footprint(WxDxH) | 260mm X 400mm X 2605mm | ||
Weight | 11kg | ||
Power usage | AC 100 to 125 V / 200 to 240 V (50/60 Hz). | ||
power consumption | 600VA | ||
Work environment | Tempereture:10°C~30°C Humidity:20%~85% |