Product Details

VD-650 desktop mini vertical type laminar flow air cabinet

Brand Name Drawell
Place of Origin Shanghai, China
Model Number VD-650/VD-850/HD-650/HD-850
Material stainless steel

Product Features

Desktop Laminar Flow Cabinet - Vertical Air Flow Model VD-650

Working Principle

First, the air is inhaled through the fan and then filtered by the HEPA filter through the static pressure box. After that the filtered clean air is sent out in the state of vertical or horizontal air flow, so that the operation area continues to reach the 100-level cleanliness under the control of clean air and to ensure the production of environmental cleanliness requirements.

 

Application Range

The vertical flow clean bench is noisy than horizontal clean bench because its fan is installed at the top. The wind blowing vertically so it is often used in medical engineering to ensure the operator’s health.

Vertical laminar flow clean bench is widely used in areas requiring partial cleaning, laboratories, biopharmaceuticals, optoelectronics, microelectronics, hard disk manufacturing and other fields.

 

Characteristics

1. Vertical air flow

2. Using remote to control the wind speed (two-stage wind speeds)

3.Equipped with HEPA filter. With primary filter for preliminary filtration, which can effectively extend the life span of HEPA filter

 

Technical Parameters

Model

VD-650

Clean grade

Grade 100(209 E U.S. Federal)

Number of bacteria

≤0.5per utensil.hour(90mm utensil)

Noise

≤62dB

Power

220V/50HZ

wind speed

0.25-0.45m/s

illumination

≥300LX

Working area dimension(W*D*H)

485*475*455mm

Overall dimension(W*D*H)

640*530*845mm

HEPA filter size and quantity

480*460*38*1pc

Fluorescent/UV lamp specifications and quantity

10W*1PC / 10W*1PC

 

 

Desktop Laminar Flow Cabinet - Vertical Air Flow Model VD-850

Working Principle

First, the air is inhaled through the fan and then filtered by the HEPA filter through the static pressure box. After that the filtered clean air is sent out in the state of vertical or horizontal air flow, so that the operation area continues to reach the 100-level cleanliness under the control of clean air and to ensure the production of environmental cleanliness requirements.

 

Application Range

The vertical flow clean bench is noisy than horizontal clean bench because its fan is installed at the top. The wind blowing vertically so it is often used in medical engineering to ensure the operator’s health.

Vertical laminar flow clean bench is widely used in areas requiring partial cleaning, laboratories, biopharmaceuticals, optoelectronics, microelectronics, hard disk manufacturing and other fields.

 

Characteristics

1. Vertical air flow

2. Using remote to control the wind speed (two-stage wind speeds)

3.Equipped with HEPA filter. With primary filter for preliminary filtration, which can effectively extend the life span of HEPA filter

 

Technical Parameters

Model

VD-850

Clean grade

Grade 100(209 E U.S. Federal)

Number of bacteria

≤0.5per utensil.hour(90mm utensil)

Noise

≤62dB

Power

220V/50HZ

wind speed

0.25-0.45m/s

illumination

≥300LX

Working area dimension(W*D*H)

685*475*455mm

Overall dimension(W*D*H)

840*530*845mm

HEPA filter size and quantity

680*460*38*1pc

Fluorescent/UV lamp specifications and quantity

15W*1PC / 15W*1PC

 

 

Desktop Laminar Flow Cabinet - Horizontal Air Flow Model HD-650

Working Principle

First, the air is inhaled through the fan and then filtered by the HEPA filter through the static pressure box. After that the filtered clean air is sent out in the state of vertical or horizontal air flow, so that the operation area continues to reach the 100-level cleanliness under the control of clean air and to ensure the production of environmental cleanliness requirements.

 

Application Range

Horizontal flow work bench noise is compared small, so it is usually used in electronic industry, which has little effect to health.

Horizontal laminar flow is widely used in electronics, national defense, precision instruments, meters, pharmaceutical industries, etc.

 

Characteristics

1. Horizontal air flow

2. Using remote to control the wind speed (two-stage wind speeds)

3.Equipped with HEPA filter. With primary filter for preliminary filtration, which can effectively extend the life span of HEPA filter

 

Technical Parameters

Model

HD-650

Clean grade

Grade 100(209 E U.S. Federal)

Number of bacteria

≤0.5per utensil.hour(90mm utensil)

Noise

≤62dB

Power

220V/50HZ

wind speed

0.25-0.45m/s

illumination

≥300LX

Working area dimension(W*D*H)

485*385*455mm

Overall dimension(W*D*H)

640*530*845mm

HEPA filter size and quantity

480*460*38*1pc

Fluorescent/UV lamp specifications and quantity

10W*1PC / 10W*1PC

 

Desktop Laminar Flow Cabinet - Horizontal Air Flow Model HD-850

 

 

 

Working Principle

First, the air is inhaled through the fan and then filtered by the HEPA filter through the static pressure box. After that the filtered clean air is sent out in the state of vertical or horizontal air flow, so that the operation area continues to reach the 100-level cleanliness under the control of clean air and to ensure the production of environmental cleanliness requirements.

 

Application Range

Horizontal flow work bench noise is compared small, so it is usually used in electronic industry, which has little effect to health.

Horizontal laminar flow is widely used in electronics, national defense, precision instruments, meters, pharmaceutical industries, etc.

 

Characteristics

1. Horizontal air flow

2. Using remote to control the wind speed (two-stage wind speeds)

3.Equipped with HEPA filter. With primary filter for preliminary filtration, which can effectively extend the life span of HEPA filter

 

Technical Parameters

Model

HD-850

Clean grade

Grade 100(209 E U.S. Federal)

Number of bacteria

≤0.5per utensil.hour(90mm utensil)

Noise

≤62dB

Power

220V/50HZ

wind speed

0.25-0.45m/s

illumination

≥300LX

Working area dimension(W*D*H)

685*385*455mm

Overall dimension(W*D*H)

840*530*845mm

HEPA filter size and quantity

680*480*38*1pc

Fluorescent/UV lamp specifications and quantity

15W*1PC / 15W*1PC

 

 

 

 

 

VD-650 desktop mini vertical type laminar flow air cabinet

 

Product display

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

Case

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

Company profile

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

Exhibition

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

Packing

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

Payment method

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

FAQ

 

VD-650 desktop mini vertical type laminar flow air cabinet 

 

 

 

Contact us

 

VD-650 desktop mini vertical type laminar flow air cabinetVD-650 desktop mini vertical type laminar flow air cabinet 

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now