copper electric wire cable
USD $0.2 - $3.9 /Meter
Min.Order:500 Meters
Henan Huaxing Wires And Cables Co., Ltd.
copper electric wire cable is features:
Rated temperature: 70 degrees Celsius
Rated voltage: 300 voltages
Reference standard: UL Subject 758, UL 1581 & CSA C22.2 No. 210.2
Tinned or bare, stranded or solid copper conductor, 32-16AWG.
PVC or PD insulation.
Passes UL VW-1 & CSA FT1 vertical flame test.
copper electric wire include following Model, type and data
Nominal | Conductor | Nominal | Max overall | Condcutor | Min insulated | Weight | ||
Cu | Al | Cu | Al | |||||
1.5 | 1/1.38 | 0.7 | 3.3 | 12.1 | - | 0.011 | 19.2 | - |
1.5 | 7/0.52 | 0.7 | 3.5 | 12.1 | - | 0.010 | 20.6 | - |
2.5 | 1/1.78 | 0.8 | 3.9 | 7.41 | 11.8 | 0.010 | 30.8 | 15.0 |
4 | 1/2.25 | 0.8 | 4.4 | 4.61 | 7.39 | 0.0085 | 45.5 | 21.0 |
6 | 1/2.76 | 0.8 | 4.9 | 3.08 | 4.91 | 0.0070 | 65.0 | 29.0 |
10 | 7/1.35 | 1.0 | 7.0 | 1.83 | 3.08 | 0.0065 | 110.0 | 52.0 |
16 | 7/1.70 | 1.0 | 8.0 | 1.15 | 1.91 | 0.0050 | 170.0 | 70.0 |
25 | 7/2.14 | 1.2 | 10.0 | 0.727 | 1.20 | 0.0050 | 270.0 | 110.0 |
35 | 7/2.52 | 1.2 | 11.5 | 0.524 | 0.868 | 0.0040 | 364.0 | 150.0 |
50 | 19/1.78 | 1.4 | 13.0 | 0.387 | 0.641 | 0.0045 | 500.0 | 200.0 |
70 | 19/2.14 | 1.4 | 15.0 | 0.268 | 0.443 | 0.0035 | 688.0 | 269.0 |
95 | 19/2.52 | 1.6 | 17.5 | 0.193 | 0.320 | 0.0035 | 953.0 | 360.0 |
120 | 37/2.03 | 1.6 | 19.0 | 0.153 | 0.253 | 0.0032 | 1168.0 | 449.0 |
150 | 37/2.25 | 1.8 | 21.0 | 0.124 | 0.206 | 0.0032 | 1466.0 | 551.0 |
185 | 37/2.52 | 2.0 | 32.5 | 0.099 | 0.164 | 0.0032 | 1808.0 | 668.0 |
MOQ, Capacity& Payment method
For electric wire, aerial cable and power cable, the Minimum Order Quantity is 1000 meters each type. The capacity is 20 kilometers per day.
For electric conductor(AAC,ACSR,AAAC,AASC) for transmission line, the Minimum Order Quantity is 1 ton each type. The capacity is 50 tons per day.
Our payment term is 30% deposit in advance, 70% rest against copy of B/L; or 100% irrevocable L/C at sight
Packing Pictures: