Temperature and Humidity Field Automatic Test data collection System
USD $3000 - $6000 /Set
Min.Order:1 Set
Tai'an Dearto Automation Instrument Co.,Ltd
High quality dry block well type 50 to 1200 deg C temperature calibration furnace
Manufacturer supply 334L temperature and humidity control chamber for hygrothermograph calibration
0.001 deg C resolution high accuracy digital thermometer with long stem and wireless communication
0.001 deg C fast refrigerated and heated thermostatic liquid bath
High accuracy and stability PID auto-control thermostatic -40 to 180 C liquid micro bath
DTZ-300 Series Temperature and Humidity Field Automatic Testing System is a set of temperature and humidity field testing system independently researched and developed by our engineers who have been engaged in the thermotechnical measurement and testing for long time. It is mainly used for the detection and calibration of constant temperature humidity chamber (room), high-low temperature test chamber, aging test chamber, drying chamber, cement container (room), salt spray corrosion test chamber, thermostatic water / oil bath, refrigerator, refrigerated storage, chamber-type electric furnace, high temperature charcoal stove and other temperature and humidity testing equipment. Meanwhile, in electron industry, it can be applied to the temperature rising test of electric circuit board and temperature and humidity parameter monitoring for environment test equipment, which reduces the workload of temperature field detection, reduces the laborintensity, standardizes the operation, reduces the measurement error, and is convenient for the management of enterprise's equipment file database. It is the ideal choice for realizing the calibration of temperature and humidity parameters for measurement, quality control, medicine, electron and other industries. It almost can be used for the detection and calibration of all measuring appliances orinstruments and equipments related to the two parameters - temperature and humidity.
n The data acquisition unit adopts LCD touch screen in 8.0 inches, which does not need to have supporting PC in the working field. The multichannel data acquisition unit can independently complete the data acquisition and storage (data is real-timely stored in USB flash disk). The system also can communicate with laptop in real time through RS232 or USB, so as to meet the requirements of real-time measurement and real-time assessment on site.
n The system can be used with multiple temperature measuring components:
Thermocouple: S, R, B, K, N, J, E, and T
Thermistor: Pt100
n External cold junction compensation processing. The DTZ-300 series temperature and humidity field automatic test system uses the external four-wire PT100 with accuracy better than 0.2 °C as the cold junction compensation of the thermocouple measurement channel.
n Simple and fast sensor connection method. The DTZ-300 series temperature and humidity field automatic test system and sensor are connected by push-pull air socket, and the contact resistance is less than 0.005Ω, which is simple, fast and ensures the reliability and performance index of the system connection.
n Optional sensor with special specifications. The company can provide a variety of special temperature sensors to meet the needs of different occasions.
n Optional external lithium battery. According to customer needs, an optional external lithium battery can be used for up to 12 hours.
n The system software can display the real-time temperature and humidity curve of each channel (thermocouple, thermal resistance). The curves of different channels are represented by curves of different colors. The color of the curve can be modified at any time to directly reflect the fluctuation of temperature and humidity of the measured object. . And record the measured data, you can export to Excel at any time according to your needs, query and print at any time.
n The system meets the technical indexes and requirements of national calibration specifications JJF1101-2003. It can automatically compute the deviation of temperature and humidity, the uniformity and fluctuation, and generate raw data meeting the requirements accepted by national laboratory. The software provides the template and interface for modifying the raw data and calibration certificate, for easier modification. It automatically performs the reference end compensation and corrects the verification data of sensor.
n The system can be optionally configured with GPRS remote transmission module or ZigBee wireless communication technology, to realize the remote data transmission.
n An easy-to-operate human-computer interface. In addition to the power switch, there is no mechanical button in the system. The user can set the type of temperature sensor, the number of temperature sensor channels, the number of humidity sensors, the date, time, acquisition interval and other general setting parameters through the touch screen.
Model | DTZ-300-A | DTZ-300-C |
Name | Temperature and Humidity Field Automatic Testing System | Imported temperature and humidity data collector |
Thermocouple channel | 40 | 40 or 40x2 |
Thermistor channel | 20 | 20 or 20x2 |
Humidity channel | 12/13 | |
Thermistor Resolution Ratio | 0.001℃ | 0.001℃ |
Thermocouple Resolution Ratio | 0.001℃ | 0.001℃ |
Measurement precision | ±0.05% | 0.01% |
Optional Configuration | lithium battery,wireless module | Independent research and development software system |