transformer sweep frequency response analysis (sfra) test
transformer sweep frequency response analysis (sfra) test
transformer sweep frequency response analysis (sfra) test
transformer sweep frequency response analysis (sfra) test
transformer sweep frequency response analysis (sfra) test
transformer sweep frequency response analysis (sfra) test

transformer sweep frequency response analysis (sfra) test

USD $1,600 - $8,900 /Set

Min.Order:1 Set

Supply Ability:
400 Set / Sets per Month
Port:
Tianjin/Shanghai/Shenshen/Ningbo
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
HZ
Place of Origin:
Hebei, China
Model Number:
HZ-600A
Power:
Electronic

Huazheng Electric Manufacturing (baoding) Co., Ltd.

Credit Member 4 years
Business Type: Agent
Main Products: Transformer Oil Test Series ,Transformer Test Series ,Oil Dissolved Gas Tester ,Battery tester

Product Details

transformer sweep frequency response analysis (sfra) test

Product Description

1.    Product Introduction of HZ-600C transformer sweep frequency response analysis (sfra) test

Transformer winding deformation tester for testing transformer 6kV and above voltage level of power transformer and other special purposes, power transformer in operation or in the process of transportation will suffer from all kinds of fault short-circuit or physical impact, strong electromagnetic force generated in the short-circuit current, the transformer windings may lose stability, cause local distortion the permanent deformation or displacement of bulge phenomenon, which will seriously affect the safe operation of the transformer. According to the national standard DL/T911 - 2004 by frequency response analysis method of measuring transformer winding deformation of transformer winding, through the detection of the amplitude frequency response characteristics of vertical or horizontal comparison on the test results, according to the degree of change the amplitude frequency response characteristics, determine the deformation of transformer windings may occur.

 

 2.     Main feature of HZ-600C transformer sweep frequency response analysis (sfra) test

 

  •  uses the frequency sweep method to measure the characteristics of transformer winding transformer, no hanging cover case, disassembly, winding by detecting the amplitude frequency response characteristics of 6kV and above transformer winding distortion, accurate measurement, such as deformation or displacement of bulge.
  •  measurement speed, the measurement time of a single winding less than 3 minutes
  •  frequency accuracy is very high, accuracy is higher than 0.001%
  •  digital frequency synthesis, higher frequency stability
  •  5000V voltage isolation, fully protect test computer security
  •  can load 9 curves at the same time, calculate the parameters of each curve automatically, diagnose the deformation of the winding automatically, and give the reference conclusions of the diagnosis
  •  analysis software, powerful, software, hardware targets meet the national standard DL/T911-2004.
  •  software management is user-friendly and intelligent. After setting up the parameters, you can complete all the measurements by just pressing a key
  •  software interface is simple, intuitive, analysis, storage, reporting, export, print and other menus at a glance

 

3.    Technical indicators of HZ-600C transformer sweep frequency response analysis (sfra) test

 

 

measuring speed

single-phase winding 1.5 minutes -3 minutes

output voltage

 Vpp-10V, automatic adjustment during test

output impedance

50 ohms

 input impedance

1M (response channel with 50 matching resistors)

sweep frequency range

50Hz - 2MHz or 50Hz - 10MHz (optional)

requency accuracy

0.001%

 sweep frequency

 linear or logarithmic, sweep interval and points can be arbitrarily set

curve shows

amplitude frequency curve (phase frequency curve, optional)

measurement of wide dynamic range

100dB ~ 20dB

power supply voltage

AC220V + 10%

host weight

only 2 kg

 transformer sweep frequency response analysis (sfra) test

Certifications

transformer sweep frequency response analysis (sfra) test 

Quality Control

 

Packaging & Shipping

transformer sweep frequency response analysis (sfra) test 

Our Services

From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services. The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.

 

Company Information

HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is  founded in 2008,the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

Our main products : Insulation Oil Tester, Cable Fault Locator, High Voltage Generator,transformer tester, relay protection tester,insulation resistance  tester,Power Quality Analyzer and so on.

Close to Tianjin port, the transportation is convenient. our customers come from More than 50 countries, like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.

What's more, gurantee 1 year,life long maintance .Products through the CE, ISO, IEC certification, quality and reliable, factory price.