ASTM D 6701 Water Vapor Permeability Test Apparatus For Medical Protective Clothing Materials
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Standard Gurley Method Air Permeability Testing Machine Battery Separator Film/ Paper Test
Shrinkage Film Testing Machine Air Bath Method ASTM/ ISO Standard
Building Materials Water Vapor Permeability Testing Machine Water & Desiccant Method
Sealing Test Vacuum Leakage Testing Machine For Flexible Package/ Pharmaceutical Bottle
Thickness Testing Machine Contact Type Test Instruments Plastic/ Paper Thickness Tester
Elongation/Tensile/ Puncture Test Auto Tensile Testing Machine For Polymer Film Bond Strength Test
ASTM D 6701 Water Vapor Permeability Test Apparatus For Medical Protective Clothing Materials
Product Details
Application:
Based on the humidity sensor detection method and available for the water vapor permeability test of heat exchange membranes, nonwoven fabrics and flexible barrier materials.
ASTM D 6701 Water Vapor Permeability Test Apparatus For Medical Protective Clothing Materials
Features:
features | Weighing method |
Dual weighing modules, own technology | |
18 specimens, continuously test | |
One-button test, test automatically in whole process | |
Multiple test modes optional | |
Temperature and humidity auto control | |
Data curves display | |
Computer control | |
Environment temperature and humidity sensor inside | |
Unit based on embedded system,24bit Δ-Σ AD | |
Traceable reference film calibration | |
Supports DSM system (DSM, lab data management system) |
Principles:
The specimen is clamped between the upper and lower chamber, the upper chamber is high humidity side, and the other side of specimen, lower chamber is purged by a stream of dry gas, due to the effect of water concentration gradient at two sides of the specimen, water molecules will permeate through the specimen into the dry gas side, penetrated water molecules will be carried to the relative humidity sensor which generates the proportional signal, so water vapor transmission rate will be obtained by calculating the sensor signal.
ASTM D 6701 Water Vapor Permeability Test Apparatus For Medical Protective Clothing Materials
Technical indexes:
Test range | 5 - 6500 g/m2·24h (Standard) |
Resolution | 0.001 g/m2·24h |
Specimen amount | 1 specimen |
Temperature range | 5C–95C |
Temperature accuracy | ±0.1C |
Humidity range | 100%RH (Standard) |
Humidity accuracy | ±1%RH |
Test area | 38 cm2 (Standard) |
Specimen size | >=150mm * 94mm |
Thickness | less 3mm |
Carrier gas | Dry Air, or 99.999% Nitrogen |
Carrier flow | 0~200 ml/min |
Gas interface | 1/8inch |
Power supply | AC 220V 50Hz |
Dimension | 330mm(L) * 600mm(D) * 330mm(W) |
Net weight | 30kg |