Snow Melting Double Conducting and Heating Floor in Parking Lane
USD $1 - $1 /Meter
Min.Order:100 Meters
Anhui Youyu Electric Heating Equipment Co., Ltd.
Snow Melting Electric Heating Mats Cable Systems Outdoor Rubber Snow Melting Mats
Snow Melting Double Conducting and Heating Floor in Parking Lane industrial salt for melting snow
Snow Melting Double Conducting and Heating Floor in Parking Lane snow melting mats
snow melting systems Double Conducting and Heating Floor in Parking Lane
Single conductor heating cable | Twin conductor heating cable |
1.Nickel alloy wire | 1.Nickel alloy wire |
2.8 tinned copper wire | 2.8 tinned copper wire |
3.Cross-linked PE insulation | 3.Cross-linked PE insulation |
4.Armored shield | 4.Armored shield |
5.PVC jacket | 5.PVC jacket |
The single-conductor industrial heating system assembly use an implicit connector, the core of the industrial heating system is composed of a hot-cold wire, and the outside is made up of an insulating layer, a earth wire, a shielding layer and a sheath layer.After the industrial heating system is energized, the heating wire generates heat, running between the temperature 40-60 ℃, buried in the filler layer of industrial heating system, through the way of heat conduction and far-infrared radiation to the heated body.Twin conductor industrial heating system with implicit connector, industrial heating system core by the cold and hot cable, the outside by the insulation layer, earth wire, shielding and outer sheath composition. After the industrial heating system is energized, the heating wire generates heat and runs at a temperature between 40 and 60 degrees. The industrial heating system embedded in the filling layer will be transmitted to the heating body through heat conduction and far-infrared radiation. Twin conductor industrial heating system is mainly used for floor heating, soil heating, snow melting , livestock breeding.
TXLP/1single conductor industrial heating system 220V 18.5W/M
| Power(W) | Type | Voltage(V) | Standard Length(m) | Power /Per Meter(W/M) | Resistance(Ω) |
3150 | TXLP/1/18.5 | 220 | 170.3 | 18.5 | 15.4 | |
3000 | TXLP/1/18.5 | 220 | 162 | 18.5 | 16.1 | |
2800 | TXLP/1/18.5 | 220 | 151.4 | 18.5 | 17.3 | |
2600 | TXLP/1/18.5 | 220 | 140.5 | 18.5 | 18.6 | |
2400 | TXLP/1/18.5 | 220 | 129.7 | 18.5 | 20.2 | |
2200 | TXLP/1/18.5 | 220 | 118.9 | 18.5 | 22.0 | |
2000 | TXLP/1/18.5 | 220 | 108.1 | 18.5 | 24.2 | |
1760 | TXLP/1/18.5 | 220 | 95.1 | 18.5 | 27.5 | |
1600 | TXLP/1/18.5 | 220 | 86.5 | 18.5 | 30.3 | |
1400 | TXLP/1/18.5 | 220 | 75.7 | 18.5 | 34.6 | |
1200 | TXLP/1/18.5 | 220 | 64.9 | 18.5 | 40.3 | |
1000 | TXLP/1/18.5 | 220 | 54.1 | 18.5 | 48.4 | |
850 | TXLP/1/18.5 | 220 | 45.9 | 18.5 | 56.9 | |
700 | TXLP/1/18.5 | 220 | 37.8 | 18.5 | 69.1 | |
600 | TXLP/1/18.5 | 220 | 32.4 | 18.5 | 80.7 | |
500 | TXLP/1/18.5 | 220 | 27.0 | 18.5 | 96.8 | |
400 | TXLP/1/18.5 | 220 | 21.8 | 18.5 | 121.0 | |
300 | TXLP/1/18.5 | 220 | 16.2 | 18.5 | 161.3 |
TXLP/2twin conductor industrial heating system 220V 17W/M | Power(W) | Type | Voltage(V) | Standard Length(M) | Power /Per Meter(W/M) | Resistance(Ω) |
3300 | TXLP/2/17 | 220 | 194.1 | 17 | 14.7 | |
2800 | TXLP/2/17 | 220 | 164.7 | 17 | 17.3 | |
2600 | TXLP/2/17 | 220 | 152.9 | 17 | 18.6 | |
2400 | TXLP/2/17 | 220 | 141 | 17 | 20.2 | |
2100 | TXLP/2/17 | 220 | 123.5 | 17 | 23.0 | |
1700 | TXLP/2/17 | 220 | 100.0 | 17 | 28.6 | |
1370 | TXLP/2/17 | 220 | 80.6 | 17 | 35.3 | |
1250 | TXLP/2/17 | 220 | 73.5 | 17 | 38.7 | |
1000 | TXLP/2/17 | 220 | 58.8 | 17 | 48.4 | |
840 | TXLP/2/17 | 220 | 49.4 | 17 | 57.6 | |
700 | TXLP/2/17 | 220 | 41.2 | 17 | 68.1 | |
600 | TXLP/2/17 | 220 | 35.3 | 17 | 80.7 | |
500 | TXLP/2/17 | 220 | 29.4 | 17 | 96.8 | |
400 | TXLP/2/17 | 220 | 23.5 | 17 | 121.0 | |
300 | TXLP/2/17 | 220 | 17.6 | 17 | 161.3 |
Product Structure | Technical Data | Product Structure | Technical Data |
Out Jacket | PVC | Outside Diameter | 7.5*6.5mm |
Earth Wire | Tinned Copper Wire | Rated Voltage | 220V(customize) |
Shield | Copper Foil + Copper Wire | Power Output | 17w/m (customize) |
Conductor | Alloy Resistance Wire | Cold Length | 2.25m |
Conductor Insulation | XLPE | Max Surface Temperature | 65℃ |
Connector | Injection Connector | Min Bending Coefficient | 5D |
We are professional heating cable manufacturer founded in 2012, located in Wuhu city, Anhui Province, China. Welcome to visit our factory!
MOQ for heating mat is 500sq. m.
MOQ for self regulating heating cable is 1000m.
MOQ for constant wattage heating cable is 1000m.
MOQ for thermostats is 50 pieces.
Yes, you can place sample order to check the quality and testing it. Parts of samples are free of charge. Delivery cost is on buyer's account.
Normally within 7~15 days, big order should be negotiated.
T/T, L/C, Western Union, Paypal, Alibaba secure payment, D/P.
25 years for heating cable & heating mat.
2 years for for constant wattage/self-regulating heating cable and thermostats.
Yes, we are professional in providing OEM and ODM service. We support both standard and customized products, we can put your logo on the products. Our experienced R&D team will support technical questions.
1. All the raw materials by ICQ(Incoming quality control).
2. IPQC(In Processing Quality control).
3. QC fully inspection before packing.
4. Before shipment, do fully inspection again.
Self Regulating Heating Cable Constant Wattage Heating Cable Heating Cable
Thermostat Underfloor Heating Mat Snow Melting Mat