rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable
rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable
rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable
rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable
rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable
rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable
rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

USD $0.5 - $0.5 /Meter

Min.Order:100 Meters

Supply Ability:
50000 Meter / Meters per Month
Port:
Any port in China
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
youyu
Place of Origin:
Anhui, China
Model Number:
customized

Anhui Youyu Electric Heating Equipment Co., Ltd.

Business license
Business Type: Manufacturer
Wuhu Anhui China
Main Products: Drainline Heating Cable ,MI Armored Heating Cable ,Single & Twin Conductor Heating Cable ,Constant Wattage Heating Cable

Product Details

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

Product Description

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

Product Introduction

Electric self-regulating temperature heating cable is the only one of electric thermostatic product of new generation, constructed of a semiconductor heater and two parallel bus wires with the addition of insulation layer. The heating elements are parallel to each other and its resistivity has a high Positive Temperature Coefficient” PTC”.

In each heating tracing band, circuits between the bus wires change with the ambient temperature. As temperature decreases, the heater’s resistance decreases which produces more output wattage; conversely, as temperature increases, resistance increases which lower the output wattage, loop back and forth.

The advantage of electric self-regulating temperature heating cable with other heating tracing products is that the temperature can be regulated automatically in a proper range.

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

Product Dispaly

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

1.Tinned copper wires

2.Self-regulating conductive core

3.Thermoplastic insulation

4.Metal braid

5.Thermoplastic jacket

Product Application

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable

self-regulating heating cable

self-regulating heating cable widely used in petroleum, chemical, steel, electricity and other fields.For industrial

pipelines, storage tanks and equipment with temperature control, heating, antifreezing.It’s applies to common areas,

dangerous areas, corrosive areas, explosion-proof areas and other complex environment.

Technical Parameter

Type

Power

(W/M 10℃)

Max maintain temp(℃)

Max.

exposure temp(℃) 

Min. installation temp(℃) 

Max. length of single power supply

 

Low temperature series

10,15,25,35

70℃±5℃

105℃

-60℃

7*0.5  100meters;

19*0.32 120meters.

Medium temperature series

35,45,50,60

105 ℃ ± 5 ℃

135℃

-40℃

7*0.5  100meters;

19*0.32 120meters

High temperature series

35,50,60

135 ℃ ± 5 ℃

155℃

-30℃

7*0.5  100meters;

19*0.32 120meters 

Company Information

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable 

Client & Certificate

rain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cablerain gutter antifreeze heating cable cable for heating ceilings stainless steel corrugated heating cable 

FAQ
1. How much electricity is consumed per hour?
Consider an average room size of 100m2 . The heated area is approximately 80%, or 80m2 .
In the case of the 150W mats, when the heater is ON, the hourly consumption is 1500W times 80m2.
When the recommended thermostat is turned on, take 100m2 as an example. The room is filled with heat about 20min~30min, which is between 450W and 750W. Of course, the specific cost depends on your electricity consumption and electricity unit price.
 
2. Do I use insulation materials?
We recommend that you use insulation materials. On the one hand, it is for your safety considerations, on the other hand, because it can lock the heat, the preheating will be faster, and the power consumption will be reduced.
 
3. Is it safe to use in a humid place?
Yes, our products are of high quality and have a grounding wire.
 
4.  How long is the warranty time?
25 years for heating cable & heating mat.
2 years for for constant wattage/self-regulating heating cable and thermostats.
 
5. Can I crop it?
Yes, you can crop the grid.
 
6. What is the thickness of the cable?
The cable is 3.5mm thick.

Contact Supplier

Ms. Joanna Lu Sales Executive Chat Now
Telephone
86-553-2667735
Mobile
86-14755302790
Skype
86 14755302790
Address
High-tech Industrial Development Zone Wuhu,Anhui
Whatsapp
86 14755302790

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category