ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor
ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor
ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor
ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor
ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor
ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor
ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

USD $0.3 - $5 /Meter

Min.Order:1000 Meters

Supply Ability:
50000 Kilometer / Kilometers per Month
Port:
Qingdao
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
RMJT
Place of Origin:
Henan, China
Model Number:
ACSR peacock conductor
Type:
High Voltage
Application:
Overhead
Conductor Material:
Aluminum

People\'s Cable Group Co., Ltd.

Business Type: Business Service (Transportation, finance, travel, Ads, etc)
Main Products: Power Cable ,Overhead cable ,Bare Conductor ,Control cable

Product Details

1. Specification:
(1) all aluminium conductor (AAC)

(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)

(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)

(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

2.Applications

Peacock Conductor(AAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

 

3. Service Performance

(1).The permissible long-time operating temperature for aerial conductor is 70oC.

(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.

(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.

(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.

 

4. Product Performance

(1).The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.

(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.

(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.

a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.

b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.

 

5. Material Standard

(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).

(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.

(3).Production can be arranged according to customers requirements for material standard,etc.

Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced

 

Code Word

AWG or MCM

Stranding and wire Da.

Approx.

Overall Dia.

Weight

Nominal

Breaking load

 

 Max.D.C..Resistance at 20°C

Al

St

 

Al

St

Total

 

 

   mm

mm

mm

Kg/m

Kg/km

Kg/km

kN

Ω/km

Hen

477

30/3.20

7/3.20

22.40

671

441

1112

105.34

0.1201

Osprey

556.5

18/4.47

1/4.47

22.35

777

122

899

60.88

0.1022

Parakeet

556.5

24/3.87

7/2.58

23.22

781

286

1067

88.2

0.1027

Dove

556.5

26/3.72

7/2.89

23.55

781

359

1140

101.03

0.1027

Eagle

556.5

30/3.46

7/3.46

24.21

783

515

1298

122.92

0.1030

Peacock

605

24/4.03

7/2.69

24.20

849

311

1160

95.88

0.0945

Squab

605

26/3.87

7/3.01

24.51

850

390

1240

108.14

0.0945

WoodDuck

605

30/3.61

7/3.61

25.25

851

560

1411

128.84

0.0947

Teal

605

30/3.61

19/2.16

25.24

851

548

1399

133.59

0.0947

Kingbird

636

18/4.78

1/4.78

23.88

889

139

1028

69.55

0.08945

Rook

636

24/4.14

7/2.76

24.84

893

326

1219

100.83

0.08989

 

ACSR peacock conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

ASTM - B 232 ACSR Peacock 605 KCMIL/MCM Conductor

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories