95 sq mm aluminium pvc insulated power three phase drop cable
95 sq mm aluminium pvc insulated power three phase drop cable
95 sq mm aluminium pvc insulated power three phase drop cable
95 sq mm aluminium pvc insulated power three phase drop cable
95 sq mm aluminium pvc insulated power three phase drop cable
95 sq mm aluminium pvc insulated power three phase drop cable
95 sq mm aluminium pvc insulated power three phase drop cable

95 sq mm aluminium pvc insulated power three phase drop cable

USD $0.07 - $1.77 /Meter

Min.Order:500 Meters

Supply Ability:
2147483647 Meter / Meters per Month
Port:
Qingdao Tianjing Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
RMJT
Place of Origin:
Henan, China
Model Number:
YJLV22,YJV32,YJLV32,VV32,

People\'s Cable Group Co., Ltd.

Business Type: Business Service (Transportation, finance, travel, Ads, etc)
Main Products: Power Cable ,Overhead cable ,Bare Conductor ,Control cable

Product Details

Product Description

95 sq mm aluminium pvc insulated power three phase drop cable

*APPLICATIONS:
Covered line Wire is used primarily for 600v overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
*CONSTRUCTION:
The conductors are 1350-H19 Aluminum Wire ,6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HDPE) or cross-linked polyethylene(XLPE).

Duplex Service Drop---Aluminum Conductor

*APPLICATIONS:
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction.
To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
*CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum.
Insulated with either polyethylene or cross-linked polyethylene (XLPE).
Neutral messengers are concentrically stranded 6201, AAC, or ACSR.



Nominal cross section
Neutral core
Phase core


weight (kg/km)
Allowable ampacity (A)
AAC

LBS
AAC
Insulation thickness(mm)

XLPE

PE
NO
diameter
(mm)
NO
diameter(mm)
1*6AWG+1*6AWG
7
1.56
563
1
4.11
1.14
92
85
70
1*6AWG+1*6AWG
7
1.56
563
7
1.56
1.14
94
85
70
1*4AWG+1*4AWG
7
1.96
881
1
5.19
1.14
139
115
90
1*4AWG+1*4AWG
7
1.96
881
7
1.96
1.14
141
115
90
1*2AWG+1*2AWG
7
2.47
1350
7
2.47
1.14
216
150
120
1*1/0AWG+1*1/0AWG
7
3.12
1990
19
1.89
1.52
347
205
160

Triplex Service Drop---Aluminum Conductor

*APPLICATIONS:
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made.
To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
*CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum.
Insulated with either polyethylene or cross-linked polyethylene (XLPE).
Neutral messengers are concentrically stranded 6201, AAC, or ACSR.


AWG or kcmil
Bare Neutral Messenger
Phase Conductor


Weight kg/km
Allowable Ampacities(A)
AAC
Rated Strength lbs.
AAC
Insul. Thick. mm

XLPE

PE
NO.
Dia.mm
NO.
Dia.mm
2*6AWG+1*6AWG
7
1.56
563
1
4.11
1.14
146
85
70
2*6AWG+1*6AWG
7
1.56
563
7
1.56
1.14
150
85
70
2*4AWG+1*4AWG
7
1.96
881
1
5.19
1.14
219
115
90
2*4AWG+1*4AWG
7
1.96
881
7
1.96
1.14
224
115
90
2*2AWG+1*2AWG
7
2.47
1350
7
2.47
1.14
338
150
120
2*1/0AWG+1*1/0AWG
7
3.12
1990
7
3.12
1.52
544
205
160
2*1/0AWG+1*1/0AWG
7
3.12
1990
19
1.89
1.52
545
205
160
2*2/0AWG+l*2/0AWG
7
3.5
2510
7
3.5
1.52
671
235
185
2*3/0AWG+l*3/0AWG
19
2.39
3310
19
2.39
1.52
830
275
215
2*4/0AWG+l*4/0AWG
19
3.25
4020
19
3.25
1.52
1476
315
245
2*336.4+1*336.4
19
3.38
6146
19
3.38
2.03
1649
420
325


Quadruplex Service Drop---Aluminum Conductor
*APPLICATIONS:

Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made.
To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
*CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum.
Insulated with either polyethylene or cross-linked polyethylene (XLPE).
Neutral messengers are concentrically stranded 6201, AAC, or ACSR. Conductors are manufactured with ridges for phase identification (one conductor one ridge, one conductor two ridges, one conductor plain.)


AWG or kcmil
Bare Neutral Messenger
Phase Conductor

Weight kg/km
Allowable Ampacities(A)
ACSR
Rated Strength lbs.
AAC
Insul. Thick. mm

XLPE

PE
No.
Dia. mm
No.
Dia. mm
3*6AWG+1*6AWG
1,6
1.68
1190
1
4.11
1.14
221
75
60
3*6AWG+1*6AWG
1,6
1.68
1190
7
1.56
1.14
227
75
60
3*4AWG+1*4AWG
1,6
2.12
1860
1
5.19
1.14
331
100
80
3*4AWG+1*4AWG
1,6
2.12
1860
7
1.96
1.14
338
100
80
3*2AWG+1*2AWG
1,6
2.67
2850
7
2.47
1.14
511
135
105
3*1/0AWG+1*1/0AWG
1,6
3.37
4380
19
1.89
1.52
824
180
140
3*2/0AWG+l*2/0AWG
1,6
3.78
5310
19
2.13
1.52
1015
205
160
3*3/0AWG+l*3/0AWG
1,6
4.25
6620
19
2.39
1.52
1254
235
185
3*4/0AWG+l*4/0AWG
1,6
4.77
8350
19
2.68
1.52
1554
275
210
3*336.4+1*336.4
1,18
3.47
8680
19
3.38
2.03
2321
370
280
3*336.4+l*4/0AWG
1,6
4.77
8350
19
3.38
2.03
2221
370
280
STANDARS:
ASTM B-230 - Aluminum Wire 1350-H19 for Electrical Purposes
ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors
ASTM B-232 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy
ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy
Product name:
Iec Compact ABC conductor Cable
Voltage:

U0/U=0.6/1KV
Technical data:
1. Maximum operating temperature 90 degrees. 
2. Maximum short circuit temperature 250 degrees
Application field:
1. Areas where underground networks are expensive.
2. Electrification of rural areas
Road conductor type:
1 AAC: all aluminum bare wire.
Bare conductor of ASC: aluminum strand.
2 AAAC: all aluminum alloy bare conductor.
Bare conductor of AASC: aluminum alloy stranded wire.
3 ACSR: steel core aluminum wire
If you like this product, please click to contact us

People's Cable Group Co., Ltd.

People's Cable Group Co., Ltd. Was founded in 2007, with good transport facilities which adjacent to the 310 national highway-Lian Huo highway. Our company had 2 factories(Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. The real capital assets more than 10 million USD, with 630 staff members, 65 of which are professional and technical experts.
Our mainly products as follow:
1.PVC insulated electric wire whatever copper conductor,aluminum conductor,CCA(copper clad aluminum),CCS(copper clad steel).
2.PVC insulated power cable and xlpe insulated power cable with or without armor upto 35kv.
3.Rubber cable like welding cable, mining cable, control cable and so on.
4.Aerial bundled cable(ABC cable) up to 10kv, like Duplex ABC cable, Triplex ABC cable, Quadruplex ABC cable and so on.
5.Bare conductor like AAC, AAAC, ACSR, AACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire and so on.
pakaging & shipping
FAQ

Q1:When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your email so that we 

will regard your inquiry priority.
Q2.How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
Q3.How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. 

The samples will be sent to you via express and arrive in 3~5 days. 
Q4.What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~