2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size
2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size
2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size
2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size
2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size
2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size
2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size

2/3/4 Core Aluminium Twisted Aerial Bundle ABC Cable Size

USD $1.3 - $3.7 /Meter

Min.Order:1000 Meters

Supply Ability:
2147483647 Kilometer / Kilometers per Month
Port:
Qingdao
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
RMJT
Place of Origin:
Henan, China
Model Number:
overhead abc cable
Application:
Overhead
Conductor Material:
Aluminum

People\'s Cable Group Co., Ltd.

Business Type: Business Service (Transportation, finance, travel, Ads, etc)
Main Products: Power Cable ,Overhead cable ,Bare Conductor ,Control cable

Product Details

ASTM overhead ABC cable

1.Introduction 

overhead ABC Cable are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. They can improves safety and reliance of electrified wire netting.

 

2.Construction

 

Phase conductors are concentrically stranded EC Grade aluminum wires, insulated with either black weather resistant cross linked polyethylene (XLPE) or polyethylene (PE). The conductor insulation is marked with longitudinal ridges for phase       identification.

Neutral messengers are concentrically stranded AAC or 6201 Alloy or ACSR. Neutral messenger can either be bare or insulated, depending on ABC design.

 

3.Standards

 

1). B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

2). B-231 Aluminum Conductors, Concentric-Lay-Stranded.

3). B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

4). B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.

5). B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).

6). Duplex Aerial Bundled Cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

4.Type

Duplex  overhead ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160

 

Triplex overhead ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

 

Quadruplex  overhead ABC Cable

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun

  