Single-core XLPE insulated armoured medium voltage 10kV power cable
USD $1 - $50 /Meter
Min.Order:200 Meters
People\'s Cable Group Co., Ltd.
Aerial Bundle PVC Cable Wire Electrical Copper Aluminum Conductor XLPE Insulated Industrial Cables
Copper Conductor XLPE Insulated Halogen Free N2XH Power Cable
25mm 50mm 120mm 16mm 3 core 4 core LV steel wire aluminium armoured cable
0.6/1kv cu/xlpe/swa/pvc power cable red 95mm pvc power cable
RMjT XLPE PVC Industrial Copper Electrical Power Cable Wires
1. Company profile:
2. IEC standard single-core XLPE insulated copper conductor armoured medium voltage power cable
XLPE insulated power cables for rated voltages up to 6 /6 kV (6/10kV)
Introduction
Single-core XLPE insulated copper conductor armoured medium voltage power cable for rated voltages up to 6/6 kV (6/10kV) are fit for AC50Hz distribution lines for the same rated voltages. The mechanical and electrical properties of these cables are accordantant with GB/T 12706-2008 Power cables extruded ed ed d'Ordon and its accessories Of rated voltages 1 kV
Instruction of single-core XLPE insulated copper conductor armoured medium voltage power cable application.
1. Rated voltages : 6 / 6kv ( 6 /10kv)
2. The ambient temperature for cable installation: ≥ 0°C
3. Maximum conductor temperature in normal operation : ≤ 90 °C
4. Max operating temperature of conductor. when cable short-circuited
(5s maximun duration) : 250 °C
5. Permissible bending radius:
Single cable : [20(D+d)±5%] , mm
Actual overall diameter , mm
Actual diameter of conductor , mm
Specification of underground medium voltage Power Cable
Type | Core unmber | Rating(kV) | |||
6/6.6/10 | |||||
Normal cross sectional area of conductor | |||||
YJV YJ LV YJY YJLY YJV62 YJLV62 YJV62 YJLV62 YJV62 YJ LV62 YJV62 YJLV62 | 1 | 25~630 | |||
YJV YJLV YJY YJLY YJV22 YJLV22 YJV23 YJLV23 YJV32 YJLV32 YJV33 YJLV33 YJV42 YJLV42 YJV43 YJLV43 | 3 | 25~400 |
6/10kV single-core XLPE insulated copper conductor armoured medium voltage power cable | ||||||||
Normal cross-section area of conductor | Overall diameter of conductor | Normal thickness of insulation | Thickness of inner sheath | Diameter of steel wire | Normal thickness of outer sheath | Approx. overall diameter | Approx. weight kg/km | |
mm² | mm | mm | mm | mm | mm | mm | YJV32 | YJY33 |
25 | 6.0 | 3.4 | 1.2 | 1.6 | 1.8 | 27 | 1456 | 1357 |
35 | 7.0 | 3.4 | 1.2 | 1.6 | 1.8 | 28 | 1610 | 1507 |
50 | 8.1 | 3.4 | 1.2 | 1.6 | 1.9 | 29 | 1804 | 1692 |
70 | 9.9 | 3.4 | 1.2 | 1.6 | 1.9 | 31 | 2105 | 1984 |
95 | 11.5 | 3.4 | 1.2 | 1.6 | 2.0 | 34 | 2697 | 2562 |
120 | 12.9 | 3.4 | 1.2 | 2.0 | 2.1 | 35 | 3034 | 2887 |
150 | 14.3 | 3.4 | 1.2 | 2.0 | 2.1 | 37 | 3384 | 3230 |
185 | 16.0 | 3.4 | 1.2 | 2.0 | 2.2 | 39 | 3842 | 3675 |
240 | 18.4 | 3.4 | 1.2 | 2.0 | 2.2 | 41 | 4564 | 4366 |
300 | 20.6 | 3.4 | 1.2 | 2.0 | 2.3 | 43 | 5272 | 5075 |
400 | 23.3 | 3.4 | 1.3 | 2.5 | 2.5 | 48 | 6731 | 6496 |
500 | 26.7 | 3.4 | 1.3 | 2.5 | 2.6 | 51 | 8037 | 7776 |
630 | 30.4 | 3.4 | 1.4 | 2.5 | 2.7 | 55 | 9686 | 9388 |
Contact