MY-B026 400nm-800nm Elisa Plate Reader for sale

MY-B026 400nm-800nm Elisa Plate Reader for sale

USD $2,000 - $3,000 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
guangzhou
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
MAYA
Place of Origin:
Guangdong, China
Model Number:
MY-B026

Guangzhou Maya Medical Equipment Co., Ltd.

Business Type: Association
Main Products: Medical X-ray machine ,Laboratory equipment ,Dental equipment ,Patient monitor

Product Details

OEM Service

MY-B026 400nm-800nm Elisa Plate Reader for sale 

MY-B026 400nm-800nm Elisa Plate Reader

Product Description

 

1. INTRODUCTION

1.1  Characters

The Microplate Reader is a semiautomated benchtop instrument focused on clinical immunity-test in hospitals or epidemic preventing stations. It has good characters such as high sensitivity, high accuracy, 

high speed of detection and the easiness of operation etc. Display is a liquid crystal one with alphanumeric and

 graphic options. Parameters can be checked on the display without using difficult command sequences.

1.2 Main Functions

The instrument is compatible with registered diagnostic EIA kit, primarily used in hospitals or some detection 

related to clinical immunology.

 

MY-B026 400nm-800nm Elisa Plate Reader for sale

 

2 Function and Technical Specifications 

2.1Fundamental parameters

1) Range of working wavelength :400nm-800nm; 

2) Range of detection:0.000A -4.000A;

3) Resolving power: 0.001 A;

4) Filters when leaving factory: 405nm, 450nm, 492nm, 630 nm, with the maximum array of 10 filters between 400nm-800nm simultaneously.

5) Reading speed: single wave 5s, dual wave 10s;

6) Dimension: 420×325×210 mm(l×h×w)

7) Weight: 10 kg

 2.2Technical Specifications

(1) Characters of the filters

Table 1: Characters of the Filters

Accuracy of  wavelength  (nm)

Half-width(nm)

±3.0

≤12

 

 

(2)  The errors of absorbance accuracy are as follows:

Table 2: Absorbance Accuracy

Absorbance (A)

Accuracy Error

0.000-2.000

±0.01

>2.000-3.000

±0.05

>3.000-4.000

±0.15

(4) The Linearity Error are as follows:

Table 3: Linearity of the Instrument

Absorbance (A)

Error (%)

0.000-2.000

 ±1.0 

>2.000-3.000

±2.0

>3.000-4.000

±5.0%

 

(5) Reproducibility Error: ≤0.5%;

(6) Stability Error: ≤±0.005A/10min;

2.3 Main function

1) Provided with power on self-checking. Error data will display on LCD monitor if something wrong with the photoelectric system. 

2)Filter choosing-mode: automatically

3) Checking mode: single wave/dual wave detection; single aperture /dual aperture detection

4) Imput mode:key in touch screen;

5) Imput format: imput capital letter/lowercase letter/number at random;

6)Item parameters: Provided with function of set/save/ inquiry 120 detection parameters , to be called in later usage.

7)Defection of calibration: with the function of calibration-defection,which can save/modify 120 parameters of calibration and curves.

8)Detecting method:absorbance/qualitative/quantitative detection;

Qualitative test: single critical value checking; dual-critical value ,threshold level testing,gray-area setting;

Quantitative test:single point,parabolic interpolation, linear regression, semi-logarithm regression, logarithm regression, logit-log , enzyme kinetics, PCR testing;

9)Saving function:can save the checking results of 100 pieces of plates to be called in later usage.

10)Output mode:

Absorbance:display/printout originally absorbable value;

Qualitative checking:display/printout absorbable value, critical value, S/CO, qualitative results;

Quantitative checking:display/printout absorbable value, density, standard reference value,quantitative results.

11) QC function:inquiry/printout the QC data and chart; 

12) Communication:equipped with RS-232 interface. 

13) With self-monitoring function(real-time)on each testing light-source signal channel.

14) With dormancy function on light-source lamp.

2.4 Work Conditions

1) Environmental temperature: 10~30°C;

2) Relative humidity: ≤70%;

3)Power Supply : 220×(1±10%)V; 50×(1±2%)Hz; Fuse φ5×20 2A;Input  power:100VA

4) Keep away from strongly electromagnetic field and avoid direct irradiation by strong light;

5) Dustproof and shockproof on worksite;no aggressive gas; pollution level:Ⅱ

6) Power supply must be firmly grounded. Transient over voltage level:Ⅱ.

7) Preheating time: 10min 

8)Don’t use instrument in damp environment

Company Information

MY-B026 400nm-800nm Elisa Plate Reader for saleMY-B026 400nm-800nm Elisa Plate Reader for sale 

Certificate

MY-B026 400nm-800nm Elisa Plate Reader for sale 

Our Services

 MY-B026 400nm-800nm Elisa Plate Reader for sale

1. For all your inquires about us,we will reply you in  detail within  24 hours

 

2. We own professional team have professional attitude to recommend products and services, introducing for you.

 

3. The  product  have one year free warranty,  after it is still providing after-sales service;

 

4. We offer OEM services. Can print your own logo on the product;

 

5. We have very experienced engineers ,can help you better useour products.

 

Your satisfaction is our duty! It will be our great honor to serve you. We do hope we can offer you more help in medical field and build the long term business relationship with you.

FAQ

MY-B026 400nm-800nm Elisa Plate Reader for sale

Q: How to buy your products ?

A: For some products we have on stock , you can take away the products after you arrange the payment ; If we don’t have stock ,we will start the production once getting the payment .

Q: What’s the warranty for the products ?

A: The free warranty is one year from the date of commissioning qualified .

 

Q: Can we visit your factory ?

A: Of course , welcome to visit our factory if you come to China .

 

Q: How long is the validity of quotation ?

A: Generally , our price is valid within one month from the date of quotation . The price will be adjusted appropriately as the price fluctuation of raw material in the market .

 

Q: What’s the production date after we confirm the order ?

A: This depend on the quantity . Normally , for the mass production ,we need about one week to finish the production . Please contact us for more detail information .

Packaging & Shipping

 Packaging

Standard export corrugated paper board cartons or wooden box

 Pallet

 Plastic/ Wooden pallet

 Shipping

 By sea/ By air/ By courier (DHL, FEDEX, UPS, TNT)

MY-B026 400nm-800nm Elisa Plate Reader for saleMY-B026 400nm-800nm Elisa Plate Reader for sale 