Relight 265nm 275 nm germicidal uv-c uv light disinfect led module strip
USD $31 - $35 /Piece
Min.Order:500 Pieces
Shenzhen Starlight Technology Co., Ltd.
Indoor sterilization uvc led module 280*20mm 3535 led module for air outflow
Factory supply 140/280*20mm uvc led module lighting 265nm 275nm 285nm for indoor sterilization
Indoor sterilization uvc led 275nm 3535 led module for school
Relight Indoor UVC sterilization module DC 12V/24V uvc led 275nm 3535 led module
Relight 265nm 275 nm germicidal uv-c uv light disinfect led module strip
Features
² Peak Wavelength: 265-285nm
² Radiant Flux :96mW
² Fordward Voltage: 12-24V
² Solutions for Linear light/Troffer
² Poke in wiring connectors
Dimensions
² Length : 140mm /5.5inch - 280mm /11inch
² Width :20mm/0.79inch - 20mm/0.79inch
² Heigth : 4mm/0.16inch - 4mm/0.16inch
Characteristics
Absolute Max current | 400mA/CH |
Rated power | Typical power(±10% tolerance) |
Protection | IP20 |
Storage temperature | -30-85℃ |
Operation temperature | -30-80℃(Ts of led components) |
Beam Angle | 120 deg |
Connectors | Poke-in Type |
Spectral Power Distribution
Package
Type | Detail | Per PVC tube | Per carton |
CM280x20A | Modules ----pcs | 1 | 800 |
Weight ----Kg | 0.028 | 22 | |
Dimension ----mm | 300*26*8 | 700*320*320 |
Installation
u This module should be mounted using the mounting slots provided.
u Nylon washers should be used on the top side to prevent the screw head from making electrical contact
with traces.
u This module should be mounted to the metal surface or part. It is better to transfer heat away from the
module to the fixture.
u LEDs should not be contacted during installation to avoid damage.
u Wire connectors will accept 20-24AWG solid or bonded stranded wire.
Safety Information
u LEDs emit very strong UV radiation
u Don't look directly into the LED light. UV radiation can harm your eyes
u To prevent even inadequate exposure, wear protective eyewear
u If LEDs are embedded in devices, please indicate warning labels against the UV light LED used
u The LED module and all its components shall not be subjected to mechanical stress
u Correct electrical polarity, or not module may be damaged
u Ensure the power supply is suitable for the total load.
u Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module.
u Installation of LED modules shall be made refering to all applicable electrical and safety standards.
u The light module needs to be mounted to a heat sink with a thermal interface material between them if
drived more than 20 watts
u Modules may be hot to the touch. Use caution when handling.