NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire
NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire
NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire
NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire
NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire
NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

USD $0.1 - $3.6 /Meter

Min.Order:100 Meters

Supply Ability:
6500000 Meter / Meters per Month
Port:
Qingdao/Tianjin/Shanghai/Ningbo/Guangzhou
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Huadong control cable.
Place of Origin:
Henan, China
Model Number:
NHXH FE180 Halogen-free power and signal cable 0.6/1 kV
Application:
Industrial
Insulation Material:
PVC
Jacket:
PVC

Henan Donghua Cable Co., Ltd.

Business Type: Other
Main Products: Power Cable ,Overhead Cable ,Special Cable ,Cable Accessories

Product Details

 
Product Description

Item name:NHXH FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

 

Application:

NHXH cables suitable for fixed installation in dry and damp environment, on or under plaster, on cable trays, same as in walls and concrete. Not intended for direct laying in ground or water. For outdoor application can be laid in tubes, but in that case should be taken all precautionary measures necessary to prevent water penetration into the tubes. Suitable for electric installations with marked fire-fighting and function preserving requirements, for alarm systems, fire sensors, evacuation elevators and other supply systems in an emergency. Appropriate for application in all situations where people and material goods need to be protected in case of fire. Recommended for public buildings frequented by a lot of people, and for buildings of high material value, for industrial complexes, electric power plants, transformer stations, municipal facilities, hotels, shopping malls, hospitals, schools, airports, underground railways and similar. Important - NHXH cables should not be laid on common trays, but on fire-resistant trays which retain their geometry in case of fire. Keeping NHXH cables in the same position in case of fire, enables additional protection of cable conductivity, by means of the mineral layer discharged around the cable at increased temperature

advantages:
- halogen-free, no release of toxic or corrosive gases under fire
- reduced smoke occurrence under fire
- no flame propagation in vertical cable bundle
- preserved electric function of the system within set time period

 

Conductor:Cu, class 1 or 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295
class 1:solid, round (RE)
class 2:multi wire stranded, round (RM) or sector (SM)
Insulation 1:mica tape, fire resistant halogen-free dielectric
Insulation 2:cross-linked halogen-free polymer, HXI1 acc. to VDE 0266, concentrically stranded cores, colour marked acc. to HRN HD 308 S2 / VDE 0293-308, with or without yellow-green protective conductor
Filler:filler applied in multi core cables, extruded halogen-free polymer or lapped glass fibres
Sheath:cross-linked thermoplastic halogen-free flame retardant polyolefin bond, HM1 or HM4 acc. to HD 604 S1 and VDE 0276-604
sheath colour:orange
 
Core colour marking:acc. to HRN HD 308 S2 / VDE 0293-308

 

Temperature range: 
during installation:-5 °C up to +50 °C
fixed installed:-15 °C up to +90 °C
max. operating temperature:90 °C
at short circuit of max. 5 s:up to 250 °C
Nominal voltage:Uο/U = 0,6/1 kV
Test voltage:4 kV
Max. tensile strength of Cu conductor:50 N/mm²
Minimal inner bending radius: 
single wire cables:15D
multi wire cables:12D
Flame retardant:IEC 60332-1
No flame propagation in vertical cable bundle:IEC 60332-3
Halogen-free:IEC 60754-1
Non-corrosive combustion gases:IEC 60754-2
Low smoke density:IEC 61034-2
Insulation integrity under fire, no short circuit FE180 – fire-resistant:IEC 60331
Circuit integrity under fire - E30:acc. to DIN 4102 part 12, 30 minutes

 

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fireNHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

Packaging & Shipping

NHXH FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

1,100 to 1,000m reeled in carton drum or according to customers' requirement.
2) Outer packing: wooden case, carton box.
3) Other packing requirement according to client's request.

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

Our Services

NHXH FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

1. We guarantee to offer new advanced goods.

2. We'd like to send skilled personnel to the installing place to help offer technical consultant, quantity estimation and instruction,installing, preliminary testing,and help start up running; and to answer for any defect of the product found in installing and run testing, If there's something wrong with the product, we'll give our answer within 12 hours and get to the spot within 36 hours.

3.After installaton, We'll send skilled personnel to have the preliminary test and answer for any problems emerged. We take the whole charge of the fee needed in repairing,testing or retesting within the scope of our duty required in contract.

4.During the contract's period of validity,of the project must be started all over again or the goods can not be used at all which is resulted from our faulty goods and improper files or mistakes made by our instructors, we'll change the goods at once without compensation and take charge in all expenses of reinstallation.

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

Company Information

Henan Huadong Cable Co., Ltd is a joint stock enterprise integrated incable production, research & development,and domestic& international trade.

Established year: 1988

Total asset: USD 32 million

Plant area: 30000 m2

Number of staff: 380

Engineer:20

Laboratory Inspector: 18

Production line: 18

Testing machine:25

Producing capacity each year: 320000 km.

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

NHXH FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire Standard:

Our products are produced according to the standards of GB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA and so on. 

Meanwhile we can produce based on customers' requirements and specifications.

NHXH FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fireCertificate:

The company has passed ISO90012008 quality certification, CCC China Compulsory Certification, National Electrical 

Product Safety Certification, State Construction and ProjectCommitee Recommended Manufacturer of the Transformation 

of Urban and Rural Power Grid Construction.

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire

FAQ

1.what is our payment term ?

  Our payment term is usually T/T 30% in advanced, the balance before picking up the goods or L/C at sight.

2.what is the lead time ?

  The lead time usually is 10 - 30 working days.

3.what is the package of the cable ?

  The package is usually wooden drum or steel wooden drum or coil.also according to customer’s requirment.

4.Could we provide the free sample for customer ?

  Sure, we provide the free sample for customer to checking.

NHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fireNHXH JZ/OZ FE180 Halogen-free power and signal cable 0.6/1 kV with improved properties under fire 

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Control Cables
Categories
Hi~